6F-8 IGNITION SYSTEM (ELECTRONIC IGNITION SYSTEM)
6) Measure resistance between terminals as follows by using
analog type ohmmeter.
If check result is not satisfactory, replace ignition coil assem-
bly.
Secondary coil resistance
"a" – "b" : 7.5 – 14 k
7) Install ignition coil assembly.
8) Tighten ignition coil bolts, and then connect ignition coil cou-
pler.
9) Install high-tension cord to ignition coil assembly while grip-
ping its cap.
10) Install cylinder head upper cover.
Crankshaft Position Sensor (CKP Sensor)
Refer to "Crankshaft Position Sensor" in Section 6E for removal,
inspection and installation.
Ignition Timing
NOTE:
• Ignition timing is not adjustable. If ignition timing is
out of specification, check system related parts.
• Before starting engine, place transmission gear shift
lever in "Neutral" (shift selector lever to "P" range for
A/T model), and set parking brake.
INSPECTION
1) When using SUZUKI scan tool (1), connect SUZUKI scan
tool to DLC (2) with ignition switch OFF.
Special tool
(A) : SUZUKI scan tool
2) Start engine and warm it up to normal operating tempera-
ture.
3) Make sure that all of electrical loads except ignition are
switched off.
4) Check to be sure that idle speed is within specification.
(Refer to "Idle Speed/Idle Air Control Duty Inspection" in
Section 6E.)
Ω
(at 20°C, 68°F)