Edge-Core ES4626 User Manual page 117

L3 gigabit ethernet switch
Hide thumbs Also See for ES4626:
Table of Contents

Advertisement

Function: Display the sFlow configuration state
Parameter:None
Command Mode: All Modes
Usage Guide: This command is used to acknowledge the operation state of sFlow
switch #show sflow
Sflow version 1.2
Agent address is 172.16.1.100
Collector address have not configured
Collector port is 6343
Sampler priority is 2
Sflow DataSource: type 2, index 194(Ethernet3/2)
Collector address is 192.168.1.200
Collector port is 6343
Counter interval is 0
Sample rate is input 0, output 0
Sample packet max len is 1400
Sample header max len is 50
Sample version is 4
Displayed Information
Sflow version 1.2
Agent address is 172.16.1.100
Collector address have not
configured
Collector port is 6343
Sampler priority is 2
Sflow
DataSource:
index 194(Ethernet3/2)
Collector
address
192.168.1.200
Collector port is 6343
Counter interval is 20
Sample rate is input 10000,
output 0
Explanation
Indicates the sFlow version is 1.2
Address of the sFlow sample proxy is 172.16.1.100
the sFlow global analyzer address is not configured
the sFlow global destination port is the defaulted 6343
The priority of sFlow when receiving packets from the
hardware is 2.
type
2,
One sample proxy data source of the sFlow is the
interface e3/1 and its type is 2 (Ethernet), the interface
index is 194.
is
The analyzer address of the sampling address of the
E3/1 interface is 192.168.1.200
Default value of the port on E3/1 interface sampling
proxy is 6343.
The statistic sampling interval on e3/1 interface is 20
seconds
The ingress traffic rate of e3/1 interface sampling proxy
is 10000 and no egress traffic sampling will be
performed
117

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es4650Es4626 l3Es4650 l3

Table of Contents