Odt Initial Data Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
Issue 1.0
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-03 : ODT Initial Data Setup to define the various basic timers for
the E&M Tie Line Unit.
Input Data
Item
01
02
03
04
05
06
07
08
09
10
11
12
13
2 - 608
Name
PCM Method Type
Answer Signal Time
Clear Signal (Open Loop) Detection Time
Ringing Signal Detection Minimum Time
Ringing Signal Stop Detection Time
Hook Flash Time
Pause Time
WINK/DELAY Duration Time
Incoming-WINK/DELAY Send Time
Seizure-WINK/DELAY Receive Max. Time
Receive WINK/DELAY Duration Min. Time
Receive WINK/DELAY Duration Max.
Time
Receive DP Make Minimum Time

81-03 : ODT Initial Data Setup

Input Data
0 = u-law
1= A-law
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(10~2040ms)
1~255
(60~15300ms)
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(100~25500ms)
1~255
(10~2550ms)
1~255
(10~2550ms)
1~255
(2~510ms)
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Default
0 (u-law)
6
(60ms)
7
(700ms)
10
(100ms)
7
(700ms)
20
(200ms)
50
(3000ms)
20
(200ms)
3
(300ms)
48
(4800ms)
13
(130ms)
31
(310ms)
5
(10ms)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents