Step 2: Specify the length of the code you want to change
After you specify a single or two digit code, you must tell the system how many digits
comprise the code. This is the Number of Digits Required column in the
System Numbering Default Settings on page 2-75
Step 3: Assign a function to the code selected
After entering a code and specifying its length, you must assign its function. This is
the Dial Type column in the
2-75
Dial
Types
0
1
2
3
4
5
6
2 - 74
Entering two digits lets you define codes based on the first two digits a user dials.
For example, entering 60 allows you to define the function of all codes beginning
with 60. In the default program, only
are single digit. If you enter a two digit code between 0 and 9, be sure to make
separate entries for all the other two digit codes within the range as well. This is
because in the default program all the two digit codes between 0 and 9 are
undefined.
Defining codes based on more than 2 digits require a secondary program (PRG 11-20)
to define the codes.
Table 2-3 System Numbering Default Settings on page
table. The choices are:
Dial Type Description
--- Not Used ---
Service Code
Extension Number
Trunk Access Code
Special Trunk Access
Operator Access
ARS/F-Route Access
and
use 2-digit codes. All the other codes
#
table.
Related Program
11-10 : Service Code Setup (for System Administrator)
11-11 : Service Code Setup (for Setup/Entry Operation)
11-12 : Service Code Setup (for Service Access)
11-13 : Service Code Setup (for ACD)
11-14 : Service Code Setup (for Hotel)
11-15 : Service Code Setup, Administrative (for Special
Access)
11-16 : Single Digit Service Code Setup
11-02 : Extension Numbering
11-04 : Virtual Extension Numbering
11-06 : ACI Extension Numbering
11-07 : Department Group Pilot Numbers
11-08 : ACI Group Pilot Number
11-17 : ACD Group Pilot Number
11-09-01 : Trunk Access Code
11-09-02 : Trunk Access Code
20-17 : Operator Extension
44-xx
Program 11 : System Numbering