Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
UNIVERGE SV8100
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each
T1 Trunk type.
Item
01
02
03
04
05
06
07
08
09
10
11
12
13
Programming Manual
Name
Answer Signal Detection Time
(Loop)
Answer Signal Detection Time
(Ground)
Answer Signal Detection Time
(DID)
Answer Signal Detection Time
(E&M)
Answer Signal Detection Time
(OPX)
Clear Signal Detection Time
(Loop)
Clear Signal Detection Time
(Ground)
Clear Signal Detection Time
(DID)
Clear Signal Detection Time
(E&M)
Clear Signal Detection Time
(OPX)
Ringing Signal Detection Time
(Loop)
Ringing Signal Detection Time
(Ground)
Ringing Signal Detection Time
(DID)
81-08 : T1 Trunk Timer Setup
Input Data
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~250
(8ms ~ 2000ms)
1~250
(8ms ~ 2000ms)
1~250
(8ms ~ 2000ms)
Issue 1.0
Default
15
60ms
15
60ms
15
60ms
15
60ms
15
60ms
6
600ms
6
600ms
6
600ms
6
600ms
6
600ms
10
80ms
10
80ms
10
80ms