NEC Univerge SV8100 Programming Manual page 740

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
Issue 1.0
Alarm
Type
Report
No.
3
2
0
Communicati
on fault
between
CD-CP00-US
and other
PKGs.
4
2
0
PKG S/W
Download
Error
5
0
Cooling fan
1
error
2 - 706
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The error occurred when
communicating with the
package. When the
package is broken, it
recognizes it as a
communication fault.
The unit program was not
able to be downloaded
normally.
The unit was not able to be
started normally.
The cooling fan does not
work normally.
Cause
Action
1.The unit is half.
1.Please insert the unit
2.The power-
firmly.
supply voltage of
2.The power-supply
the system is
voltage must use
outside ratings.
another power supply
3.The equipment
when is in the range of
that generates the
ratings or measuring
noise in the same
with the voltmeter, and
power supply
deviating from the rated
system as the
range.
power supply origin
3.Please use the power
of the system is
supply besides the
connected, and it
equipment with the
malfunctions
possibility of the noise
because of the
source.
power supply
4.Please separate as
noise.
much as possible and
4.The equipment to
use a main device from
which it is adjacent
the equipment by which
to of a main device,
you seem may
and has put out the
generate the radiation
radiation noise
noise.
exists, and it
5.Please ground the
malfunctions
chassis correctly.
because of the
radiation noise.
5.The chassis is
not properly
grounded.
The package
Delete slot information
software is not
that corresponds by
stored in the
PRG90-05-01 to delete
downloaded USB
package information
memory.
that had been installed
The stored
before.
package software
There is a possibility
is illegal.
that the unit program is
Package
broken though an
information that
external factor of the
had been installed
noise etc. is thought.
before remains.
Please load into the
USB memory and try
again when you back
up the unit program.
Please inquire of the
manufacturer when not
restoring it.
The cooling fan has
Confirm that the cooling
stopped working.
fan is turning.
The cooling fan has
Verify the mounting of
come off.
the cooling fan.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
When the unit
ERR
is
REC
reconfirmed,
the error is
recovered.
Please
ERR
exchange
REC
units, though
it is likely to
restore by
mounting the
unit again.
When the unit
program is
normally
downloaded,
the error is
recovered.
Replace the
cooling fan if it
is defective.