Odt Initial Data Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-03 : ODT Initial Data Setup to define the various basic timers for
the E&M Tie Line Unit.
Input Data
Item
2 - 608
Name
01
PCM Method Type
02
Answer Signal Time
03
Clear Signal (Open Loop) Detection Time
04
Ringing Signal Detection Minimum Time
05
Ringing Signal Stop Detection Time
06
Hook Flash Time
07
Pause Time
08
WINK/DELAY Duration Time
09
Incoming-WINK/DELAY Send Time
10
Seizure-WINK/DELAY Receive Max. Time
11
Receive WINK/DELAY Duration Min. Time
12
Receive WINK/DELAY Duration Max.
Time
13
Receive DP Make Minimum Time

81-03 : ODT Initial Data Setup

Input Data
0 = u-law
1= A-law
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(10~2040ms)
1~255
(60~15300ms)
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(100~25500ms)
1~255
(10~2550ms)
1~255
(10~2550ms)
1~255
(2~510ms)
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Default
0 (u-law)
6
(60ms)
7
(700ms)
10
(100ms)
7
(700ms)
20
(200ms)
50
(3000ms)
20
(200ms)
3
(300ms)
48
(4800ms)
13
(130ms)
31
(310ms)
5
(10ms)

Hide quick links: