UNIVERGE SV8100
Program 82 : Basic Hardware Setup for Extension
Level:
MF
Description
Use Program 82-04 : LCA Initial Data Setup to set the basic data of the LCA.
Input Data
Item No.
Programming Manual
Item
01
Companding Method Type
02
Ringing Frequency
03
Minimum Break Time
04
Maximum Break Time
05
Minimum Make Time
06
Maximum Make Time
07
Minimum Hook Flash Time
08
Maximum Hook Flash Time
09
Minimum Ground Flash Time
10
Minimum Off-Hook Time
11
No Detection Time after Off-Hook
12
No Detection Time after Pulse Dial
Detection
13
Loop Disconnect Time, Reversal
Time
14
Ring, Message Wait Period Time

82-04 : LCA Initial Data Setup

Input Data
0 = u-law
1 = A-law
0 = 25Hz
1 = 20Hz
2 = 16Hz
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (5ms~1275ms)
1~255 (10ms~2550ms)
1~255 (5ms~1275ms)
Issue 1.0
Default
0
1 (20Hz)
2 (10ms)
20(100ms)
2 (10ms)
20 (100ms)
21 (105ms)
200 (1000ms)
21 (105ms)
21 (105ms)
60 (300ms)
70 (350ms)
60 (600ms)
150 (750ms)
2 - 635