Program 51 : Netlink Service; Netlink System Property Setting - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
Level:
IN
Description
Use Program 51-01 : NetLink System Property Setting to define the
parameters of the NetLink feature.
Input Data
Item
No.
01
02
03
Programming Manual

Program 51 : NetLink Service

51-01 : NetLink System Property Setting

Each system must be set with its own information.
When the NetLink System ID is changed (Item 01), the system must be
reset.
Item
NetLink System ID
This is the ID of each NetLink system.
Setting should insure that no overlap
occurs between nodes.
Primary Candidate Order
When the Primary system is turned
off or disconnect from network, this
value is used to select a new Primary
system. Smaller number is higher
priority.
If this value is the same number, the
System ID (PRG51-01-01) is
referred, and the system which has
the smaller number is selected as
Primary system.
Secondary System Flag
0: NetLink is dynamically established
based on Node List in PRG51-03-01.
Primary System will be selected in
the order which the system wakes up.
1: The system will connect with Top
Priority Primary System.
If Top Priority Primary System was
not found, the system will search
Primary System like this setting is 0.
Input Data
0~50
(0 = No operation)
1~50
0
= Disable
1
= Enable
Program
51
Default
0
30
0
2 - 561