NEC Univerge SV8100 Programming Manual page 744

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
Issue 1.0
Alarm
Type
Report
No.
40
0
0
CS error noti-
fication 2.
41~49
--- Reserved ---
50
1
0
System Start
Notification
51
0
0
System Data
change
52
0
--- Reserved ---
0
53
0
--- Reserved ---
0
54
0
License
2
Management
Table Full
55
0
Regular
2
maintenance
exchange
notification.
56~59
--- Reserved ---
60
0
SIP
2
Registration
Error
Notification.
2 - 710
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
CS detected the factor that
the noise is generated
between CS-PS, BBIC
reset was executed, and it
was restored automatically.
The system started.
CD-CP00-US Upgrade is
performed or Programming
change is made.
A new TCP/IP terminal and
the DSP board were not
able to be added to the
application license
management table.
• The license management
table is registering full.
The regular maintenance
exchange day has passed.
1.The registration of the
SIP trunk to the SIP server
failed.
2.The registration of the
SIP trunk to the SIP server
failed in the authentication.
3.There is no response
from the SIP server to the
SIP registration request.
Cause
Action
1. Outgoing noise.
Please confirm the
2. Method of setting
following matter when
up CS.
happening frequently
3. Wiring to
when operating it.
connect CSIU unit
1. Please confirm CS is
with CS.
normally connected.
4. Hard defect of
2. Please confirm the
CS.
wiring between CSIU-
5. Hard defect of
CS is normal.
CSIU.
3. Please exchange
CS.
4. Please exchange
CSIU.
The system was
No action needed.
started.
No action needed.
Maximum 512
Please delete license
license information
information on an
on the TCP/IP
unnecessary TCP/IP
terminal is
terminal with
registered, and a
PRG90-44.
new terminal
cannot be
registered.
• The regular
Please do the
maintenance
maintenance
exchange day that
exchanges of pertinent
had been set with
parts, and set the next
PRG90-51
regular maintenance
exceeded it.
exchange day with
PRG90-51.
• The setting of the
1.Reconfirm the
system data is
following system data
wrong.
setting -- PRG10-12,
10-28, 10-29, 10-30,
• The setting of the
and 10-36.
router is wrong.
2.Confirm the setting of
routers.
• It is an error to the
3.Confirm whether
link of LAN.
abnormality occurs on
the net side.
• Net side trouble.
4.Reconfirm the
authentication system
data setting.
5.Reconfirm wiring and
the system data setting.
Please inquire an
uncertain point of the
maker.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
This error has
ERR
been
REC
recovered
when it is
notified.
WAR
The excess
ERR
REC
on the regular
maintenance
exchange day
is canceled by
changing
PRG90-51 or
when the
function is
invalidated,
the error is
recovered.
The error is
ERR
recovered
REC
when normally
connecting it.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents