51-16 : NetLink System Data Replication Mode Setting

Level:
IN
Description
Use Program 51-16: NetLink System Data Replication Mode Setting to set the
system data replication between the Primary and Secondary systems.
Input Data
Item
No.
01
02
03
04
05
06
Programming Manual
Item
System Data Replication Mode
Sets the synchronous mode of the system data.
When set to 1 (Setting Time Mode), the systems
are synchronized at the time set in Item 02
below.
When set to 2 (Interval Mode), the systems are
synchronized at regular time intervals set in Item
03 below.
System Data Replication Time Setting
Sets the time of day that both systems
synchronize database (when Item 01 is set to 1.)
System Data Replication Interval Setting
Sets the time interval that both systems
synchronize database (when Item 01 is set to 2).
Replication Time Stamp
Show next replication time. (Read-Only)
System Data Replication Wait Time
This sets the wait time until replication starts
when NetLink is created.
System Data Replication Interval
This program sets an interval time to start
replication to the next node after replication to
one node is completed.
Program 51 : NetLink Service
Input Data
0 = Disable
1 = Setting Time Mode
2 = Interval Mode
0000~2359
15~1440 (minutes)
Month: 0~12
Day: 0~31
Hour: 00~23
Minute: 00~59
1~86400 (seconds)
0~86400 (seconds)
Issue 1.0
Default
0
0200
30 (min)
180 sec
1 sec