Cisco MWR 2941 Router Command Reference, Release 15.0(1)MR

network-clock hold-off

To configure a hold-off value on an interface, use the network-clock hold-off command in interface
configuration mode. To remove a hold-off configuration, use the no form of this command.
Syntax Description
0
hold-off-value
Defaults
300
Command Modes
Interface configuration (config-if)
Command History
Release
15.0(1)MR
Usage Guidelines
A network holdoff timer determines the amount of time that the router waits when a synchronous
Ethernet clock source fails before taking action. After the holdoff timer expires, the router announces
the failure and switches to another clock source or holdover mode.
This command only applies to synchronous Ethernet interfaces.
Examples
This example shows how to configure a hold-off timer value on an interface:
Router# configure terminal
Router(config)# interface gigabitethernet0/0
Router(config-if)# network-clock hold-off 400
Router(config-if)#
Related Commands
Command
network-clock external
hold-off
network-clock hold-off
global
OL-23890-01
network-clock hold-off {0 | hold-off-value}
no network-clock hold-off {0 | hold-off-value}
Disables the hold-off timer.
A warning will be displayed for any value below 300 ms and above 1800 ms.
Modification
This command was introduced.
Description
To override the hold-off timer value for an external interface
Configure a general hold-off timer.
Cisco MWR 2941 Router Command Reference, Release 15.0(1)MR
network-clock hold-off