MAINTENANCE TASKS
Cleaning the sensors and the reflecting surfaces
Cleaning the Q850 sensor
10-10
Step 12.
Close the printer doors.
Note: The fuser agent message disappears after the LPS prints
between 32 and 40 sheets. Since the sheets must be processed
continuously, you may want to run 45 test pages in order to clear the
message from the system (unless the current print job contains at
least 40 pages).
This section lists the steps to clean the following:
•
Q850 sensor
•
Q1011 sensor and mirror
•
Q1106 sensor
•
Q1166 sensor
•
Q1107 sensor
•
Q1164 sensor.
Follow this procedure when directed by the Xerox Customer Support
Center personnel.
Step 1.
Open the printer right and left doors and locate area 4.
Step 2.
Raise the area 4 green handle until it locks into place (see figure
10-14).
Figure 10-14.Raising the Area 4 green handle
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS OPERATOR GUIDE