Detection and Port Configuration for Dell Compellent Arrays

Switches support the
storage array. The command configures a port for the best iSCSI traffic conditions and must be entered in
INTERFACE Configuration mode.
The following message is displayed the first time you use the
configure a port connected to a Dell Compellent storage array and describes the configuration changes that
are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for optimal
conditions to support iSCSI traffic which will cause some automatic configuration to occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree port
fast to be enabled on the port of detection.
After you execute the
Jumbo frame size is set to 12000 for all interfaces on all ports and port-channels, if it is not already
enabled.
Spanning-tree portfast is enabled on the interface.
Unicast storm control is disabled on the interface.
You must enter the
FTOS(conf-if-te-o/50# iscsi profile-compellent
Synchronizing iSCSI Sessions Learned on VLT-Lags with
VLT-Peer
The following behavior occurs during synchronization of iSCSI sessions:
If the iSCSI login request packet is received on a port belonging to a VLT lag, the information is
synced to the VLT peer and the connection is associated with this interface.
Additional updates to connections (including aging updates) that are learnt on VLT lag members are
synced to the peer.
When receiving an iSCSI login request on a non-VLT interface followed by a response from a VLT
interface, the session is not synced since it is initially learnt on a non-VL T interface through the request
packet.
A new connection log is generated by the peer that sees the login response packet. If the login response
packet uses the ICL path, it will be seen by both the peers, which in turn generate logs for this
connection.
command to configure a port connected to a Dell Compellent
iscsi profile-compellent
iscsi profile-compellent
command in INTERFACE configuration mode; for example:
iscsi profile-compellent
iscsi profile-compellent
command, the following actions occur:
command to
iSCSI Optimization | 565