Implementation Information; Important Points To Remember - Dell Force10 S4810P Configuration Manual

High-density, 1ru 48-port 10gbe switch
Hide thumbs Also See for Force10 S4810P:
Table of Contents

Advertisement

Figure 45-1. sFlow Traffic Monitoring System
Switch/Router
Poll Interface

Implementation Information

The Dell Force10 sFlow is designed so that the hardware sampling rate is per line card port-pipe and is
decided based upon all the ports in that port-pipe. If sFlow is not enabled on any port specifically , then the
global sampling rate is downloaded to that port and is to calculate the port-pipe's lowest sampling rate.
This design supports the possibility that sFlow might be configured on that port in the future. Back-off is
triggered based on the port-pipe's hardware sampling rate.
For example, if port 1 in a the port-pipe has sFlow configured with a 16384 sampling rate while port 2 in
the port-pipe has sFlow configured but no sampling rate set, FT OS applies a global sampling rate of 512 to
port 2. The hardware sampling rate on the port-pipe is then set at 512 because that is the lowest configured
rate on the port-pipe. When a high traffic situation occurs, a back-off is triggered and the hardware
sampling rate is backed-off from 512 to 1024. Note that port 1 maintains its sampling rate of 16384; port 1
is unaffected because it maintains its configured sampling rate of 16484.
To avoid the back-off, either increase the global sampling rate or configure all the line card ports with the
desired sampling rate even if some ports have no sFlow configured.

Important Points to Remember

The FTOS implementation of the sFlow MIB supports sFlow configuration via
Collection through management interface is supported on E-Series only
Dell Force10 recommends that the sFlow Collector be connected to the Dell Force10 chassis through a
line card port rather than the RPM Management Ethernet port.
E-Series TeraScale sFlow sampling is done on a per-port-pipe basis.
E-Series ExaScale, C-Series, and S-Series sFlow sampling is done on a per-port basis.
936
|
sFlow
sFlow Collector
sFlow Agent
Interface
Counters
Counters
Switch ASIC
sFlow Datagrams
Flow Samples
.
snmpset

Advertisement

Table of Contents
loading

Table of Contents