Enable PIM-SM graceful restart (non-stop forwarding capability) using the command
from CONFIGURATION mode. There are two options with this command:
nsf
is the time required by the Dell Force10 system to restart. The default value is 180 seconds.
restart-time
stale-entry-time
restarting neighbor. The default value is 60 seconds.
In helper-only mode, the system preserves the PIM states of a neighboring router while the neighbor
gracefully restarts, but the Dell Force10 system allows itself to be taken off the forwarding path if it
restarts. Enable this mode using the command
over any graceful restart configuration.

Monitoring PIM

The PIM MIB is supported only on platform
FTOS fully supports the PIM MIB as specified in RFC 5060 with some exceptions.
The following tables are not supported:
pimBidirDFElectionTable
pimAnycastRPSetTable
The OIDs related to InvalidRegisterMsgs reflect the last received invalid register message. Similarly,
the OIDs related to InvalidJoinPruneMsgs reflect the last received invalid Join or Prune message.
OIDs which refer to any timer show the time that the timer started; it is 0 otherwise.
is the maximum amount of time that the Dell Force10 system preserves entries from a
ip pim graceful-restart helper-only
e
ip pim graceful-restart
. This mode takes precedence
PIM Sparse-Mode (PIM-SM) | 785