config inline-power operator-limit

config inline-power operator-limit <milliwatts> ports <portlist>
Description
Sets the limit on the specified ports to either the default value or the specified watts.
Syntax Description
milliwatts
portlist
Default
15400 mW.
Usage Guidelines
This command sets the limit on the specified ports to either the default value or the specified watts.
Range is 3000-20000 mW. The default value is 15400 mW minimum. This command is used in
conjunction with the violation precedence and has no effect if either
selected for violation precedence using the following command:
config inline-power violation-precedence [advertised-class | operator-limit | max-class-operator | none]
ports <portlist>
Example
The following command sets the limit on ports 3 – 6 of slot 5 to 10000 mW:
config inline-power operator-limit 10000 ports 5:3-5:6
History
This command was first available in ExtremeWare 7.2.
Platform Availability
This command is available on Alpine series I/O modules only.
1906
An integer specifying milliwatts in the range of 3000 – 20000 mW.
Specifies one or more slots and ports. May be in the form 2:*, 2:5, 2:6-2:8.
or
none
advertised-class
ExtremeWare Software 7.3.0 Command Reference Guide