Power Over Ethernet Commands
• Curr—Displays the measure current in milli Amps (mA).
• Res—Displays the measured resistance in kilo Ohms (Kohms). A value greater than 100 Kohms
indicates an empty port.
• Power—Displays the measured power in watts.
• Fault—Displays the fault value:
— 0: No fault
— 1: Over voltage
— 2: Over voltage spike
— 3: Peak over current
— 4: Overload
— 8: Discovery resistance failed
— 9: Class violation
— 10: Disconnect
— 11: Discovery resistance, A2D fail
— 12: Classify, A2D fail
— 13: Sample A2D fail
— 14: Device fault, A2D fail
The detail command lists all inline power information for the selected ports. Detail output displays the
following information:
• Configured Admin State
• Inline Power State
• MIB Detect Status
• Label
• Violation Precedence
• Operator Limit
• Detection
• Reserved Power
• Inline Type
• Connect Order
• PD Class
• Max Allowed Power
• Measured Power
• Line Voltage
• Discovered Resistance
• Discovered Capacitance
• Current
• Fault Status