Extreme Networks ExtremeWare Command Reference Manual page 2211

Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

To configure a BlackDiamond switch to run diagnostics on an MSM at boot-up, use the following
command:
configure diagnostics [extended | fastpost | normal | off]
Example
The following command runs extended diagnostics on the module in slot 3 of a BlackDiamond chassis:
run diagnostics extended slot 3
A warning is displayed about the impact of this test, and you have the opportunity to continue or
cancel the test.
Running extended diagnostics will disrupt network traffic on the system.
Extended diagnostic will also execute Packet Memory Scan........
WARNING:
Device may be taken offline. To prevent this
first configure "sys-health-check auto-recovery online"
Are you sure you want to continue?
y
Extended diagnostics can cause the following messages to appear in the log:
<CRIT:SYST> task tdiagTask cpu utilization is 98% PC: 806266e8
<INFO:SYST> task tdiagTask cpu utilization is 98% PC: 806266e8
You can ignore these messages, as they indicate that the system is busy running the diagnostics.
History
This command was first available in ExtremeWare 6.1.5.
The command was modified to support the MPLS module in an ExtremeWare IP Technology Services
Release based on ExtremeWare 6.1.8b12.
The command was modified to support MSM modules in ExtremeWare 6.1.9.
The command was modified to support Alpine and Summit switches in ExtremeWare 6.2.
Platform Availability
This command is available on "i" series switches.
ExtremeWare Software 7.3.0 Command Reference Guide
yes/no
run diagnostics
2211

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware 7.3.0

Table of Contents