Operation Manual – Information Center
H3C S3100 Series Ethernet Switches
1.2.7 Setting to Output System Information to the Trap Buffer
Table 1-13 Set to output system information to the trap buffer
Enter system view
Enable the information
center
Enable system
information output to the
trap buffer
Configure the output rules
of system information
Set the format of time
stamp in the output
information
1.2.8 Setting to Output System Information to the Log Buffer
Table 1-14 Set to output system information to the log buffer
Enter system view
Enable the information
center
Enable information output
to the log buffer
Operation
system-view
info-center enable
info-center trapbuffer
[channel
{ channel-number |
channel-name } | size
buffersize]*
info-center source
{ modu-name | default }
channel
{ channel-number |
channel-name } [ { log |
trap | debug } { level
severity | state state } ]*
info-center timestamp
{ log | trap | debugging }
{ boot | date | none }
Operation
system-view
info-center enable
info-center logbuffer
[ channel
{ channel-number |
channel-name } | size
buffersize ]*
Command
Command
1-15
Chapter 1 Information Center
Description
—
Optional
Enabled by default.
Optional
By default, the switch
uses information channel
3 to output trap
information to the trap
buffer, which can holds up
to 256 items by default.
Optional
Refer to
Table 1-8
for the
default output rules of
system information.
Optional
By default, the time stamp
format of the output trap
information is date.
Description
—
Optional
Enabled by default.
Optional
By default, the switch
uses information channel
4 to output log information
to the log buffer, which
can holds up to 512 items
by default.