H3C S3100V3-EI Series Installation Manual

H3C S3100V3-EI Series Installation Manual

Hide thumbs Also See for S3100V3-EI Series:
Table of Contents

Advertisement

Quick Links

H3C S3100V3-EI Switch Series
Installation Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W106-20210427

Advertisement

Table of Contents
loading

Summary of Contents for H3C S3100V3-EI Series

  • Page 1 H3C S3100V3-EI Switch Series Installation Guide New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6W106-20210427...
  • Page 2 The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3 Preface H3C S3100V3-EI Switch Series Installation Guide describes the appearance, installation, power-on, maintenance, and troubleshooting of the H3C S3100V3-EI Switch Series. This preface includes the following topics about the documentation: • Audience. • Conventions. • Documentation feedback. Audience This documentation is intended for: •...
  • Page 4 Symbols Convention Description An alert that calls attention to important information that if not understood or followed WARNING! can result in personal injury. An alert that calls attention to important information that if not understood or followed CAUTION: can result in data loss, data corruption, or damage to hardware or software. An alert that calls attention to essential information.
  • Page 5 Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
  • Page 6: Table Of Contents

    Contents 1 Preparing for installation ·········································································· 1-1 Safety recommendations ································································································································ 1-1 Examining the installation site ························································································································· 1-2 Temperature/humidity ····························································································································· 1-2 Cleanliness ·············································································································································· 1-2 Corrosive gas limit ··································································································································· 1-3 EMI ·························································································································································· 1-4 Laser safety ············································································································································· 1-4 Installation tools ·············································································································································· 1-4 2 Installing the switch ·················································································· 2-5 Installing the switch in a 19-inch rack··············································································································...
  • Page 8: Preparing For Installation

    Preparing for installation This document is applicable to the S3100V3-EI switch series. Table1-1 describes the S3100V3-EI switch series models. Table1-1 S3100V3-EI switch series models Switch model Product code (PID) LS-3100V3-10TP-EI S3100V3-10TP-EI LS-3100V3-10TP-EI-GL LS-3100V3-18TP-EI S3100V3-18TP-EI LS-3100V3-18TP-EI-GL S3100V3-18TP-EI-DC LS-S3100V3-18TP-EI-DC LS-3100V3-28TP-EI S3100V3-28TP-EI LS-3100V3-28TP-EI-GL LS-3100V3-28TP-EI-H1 S3100V3-28TP-EI-DC LS-S3100V3-28TP-EI-DC...
  • Page 9: Examining The Installation Site

    • Make sure the power source voltage is as required. • To avoid electrical shocks, do not open the chassis while the switch is operating or when the switch is just powered off. • To avoid ESD damage, always wear an ESD wrist strap during installation. Examining the installation site The S3100V3-EI switches must be used indoors.
  • Page 10: Corrosive Gas Limit

    • Use double-layer glass in windows and seal doors and windows with dust-proof rubber strips. Use screen doors and window screens for doors and windows open to the outside and make sure the external windows are air tight. • Use dustproof materials for floors, walls, and ceilings and use wallpaper or matt paint that does not produce powders.
  • Page 11: Emi

    All electromagnetic interference (EMI) sources, from outside or inside of the switch and application system, adversely affect the switch in the following ways: • A conduction pattern of capacitance coupling. • Inductance coupling. • Electromagnetic wave radiation. • Common impedance (including the grounding system) coupling. To prevent EMI, use the following guidelines: •...
  • Page 12: Installing The Switch

    CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence. Figure2-1 Hardware installation flow Start...
  • Page 13: Attaching The Mounting Brackets To The Switch

    Table2-2 Mounting brackets applicable to the switch Switch model Mounting brackets Views S3100V3-28TP-EI S3100V3-28TP-EI-DC Mounting brackets A (provided) See A in Figure2-2. S3100V3-52TP-EI S3100V3-28TP-PWR-EI Mounting brackets B with S3100V3-10TP-PWR-EI product code S3100V3-20TP-PWR-EI See B in Figure2-2. SOHO-SWITCH-FL-02 S3100V3-20TP-PWR-EI-DC (optional) Mounting brackets C with S3100V3-10TP-EI product code S3100V3-18TP-EI...
  • Page 14: Rack-Mounting The Switch

    Figure2-3 Attaching mounting bracket A (S3100V3-28TP-PWR-EI switch) Figure2-4 Attaching mounting bracket B (S3100V3-10TP-PWR-EI switch) Figure2-5 Attaching mounting bracket C (S3100V3-10TP-EI switch) Rack-mounting the switch This task requires two people. To mount the switch in the rack: Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Verify that the mounting brackets have been securely attached to the switch chassis.
  • Page 15 One person holds the switch chassis and aligns the mounting brackets with the mounting holes in the rack posts, and the other person attaches the mounting brackets to the rack with M6 screws. M6 screws are provided only for switches shipped with mounting brackets. For switches not shipped with mounting brackets, prepare M6 screws yourself.
  • Page 16: Mounting The Switch On A Workbench

    Figure2-8 Mounting an S3100V3-10TP-EI switch in the rack Mounting the switch on a workbench IMPORTANT: • Ensure 10 cm (3.9 in) of clearance around the chassis for heat dissipation. • Do not place heavy objects on the switch. If a standard 19-inch rack is not available, you can place you switch on a workbench. To mount the switch on a workbench: Verify that the workbench is sturdy and reliably grounded.
  • Page 17 Switch model Hole distance S3100V3-20TP-PWR-EI 116 mm (4.57 in) S3100V3-20TP-PWR-EI-DC Figure2-9 Screw anchor and screw To mount the switch on a wall: Mark two installation holes on the wall. Make sure the two holes are on the same horizontal line. Table2-2 for the distance requirement between the two holes.
  • Page 18: Grounding The Switch

    Figure2-12 Installing the switch on a wall (3) Grounding the switch WARNING! Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection. The power input end of the switch has a noise filter, whose central ground is directly connected to the chassis to form the chassis ground (commonly known as PGND).
  • Page 19: Grounding The Switch With A Grounding Conductor Buried In The Earth Ground

    Figure2-13 Attaching the grounding cable to the grounding hole of the switch (S3100V3-28TP-PWR-EI switch) (1) Grounding screw (2) Ring terminal (3) Grounding sign (4) Grounding hole (5) Grounding cable Connect the other end of the grounding cable to the grounding strip. a.
  • Page 20: Connecting The Power Cord

    S3100V3-28TP-PWR-EI H3C RPS1600-A Connecting the switch to an RPS –48 VDC power source in S3100V3-18TP-EI-DC the equipment room or H3C S3100V3-28TP-EI-DC RPS1600-A Connecting the switch to an external DC DC power supply system power supply system that provides voltage within...
  • Page 21: Connecting The Switch To An Ac Power Source

    Connecting the switch to an RPS CAUTION: To connect the switch to an RPS, you must use a power cord compatible with the RPS. As a best practice, use an H3C RPS1600-A for the switch. To connect the switch to an RPS: 2-14...
  • Page 22: Connecting The Switch To An External Dc Power Supply System

    Correctly orient the DC power cord connector, and align and insert the connector into the DC-input power receptacle on the switch. See callout 1 in Figure2-18. If you cannot insert the connector into the receptacle, re-orient the connector rather than use excessive force to push it in.
  • Page 23: Verifying The Installation

    Figure2-19 Connecting the switch to an external DC power supply system (S3100V3-28TP-PWR-EI switch) Verifying the installation After you complete the installation, verify that: • There is enough space for heat dissipation around the switch, and the rack or workbench is stable.
  • Page 24: Accessing The Switch For The First Time

    As shown in Table3-1, two types of console cables can be used for connecting the switch to a configuration terminal. No serial console cable is provided with the switch. Purchase a console cable from H3C. Table3-1 Connection methods and console cables...
  • Page 25: Connecting A Usb-To-Rj45 Console Cable

    A DB9-to-RJ45 serial console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the serial console port of the switch, and a DB-9 female connector at the other end for connecting to the serial port on a configuration terminal. Figure3-2 DB9-to-RJ45 console cable Table3-2 DB9-to-RJ45 console cable signal pinout RJ-45...
  • Page 26 Click the following link, or copy it to the address bar on your browser and download the USB-to-RJ45 console driver. http://www.h3c.com/en/home/USB_to_RJ45_Console/ View the TXT file Read me in the Windows folder to check whether the Windows system of the configuration terminal supports the driver.
  • Page 27: Setting Terminal Parameters

    Figure3-5 Finishing the driver installation Connect the standard USB connector of the cable to the USB port of the configuration terminal. Connect the RJ-45 connector of the cable to the console port of the switch. Setting terminal parameters To configure and manage the switch through the console port, you must run a terminal emulator program, such as TeraTermPro, on your configuration terminal.
  • Page 28 Power on the switch. During the startup process, you can access Boot ROM menus to perform tasks such as software upgrade and file management. The Boot ROM interface and menu options differ with software versions. For more information about Boot ROM menu options, see the software-matching release notes for the device.
  • Page 29: Setting Up An Irf Fabric

    Setting up an IRF fabric You can use H3C IRF technology to connect and virtualize S3100V3-EI switches into a large virtual switch called an "IRF fabric" for flattened network topology, and high availability, scalability, and manageability. IRF fabric setup flowchart...
  • Page 30: Planning Irf Fabric Setup

    Step Description Install IRF member "Installing the switch in a 19-inch rack" or "Mounting the switch on a switches. workbench." Connect grounding cables and power "Grounding the switch" and "Connecting the power cord." cords. Power on the switches. Configure basic IRF See the IRF configuration guide or virtual technologies configuration guide for settings.
  • Page 31: Identifying Irf Physical Ports On The Member Switches

    When connecting two neighboring IRF member switches, you must connect the physical ports of IRF-port 1 on one switch to the physical ports of IRF-port 2 on the other switch. The S3100V3-EI switches can provide GE IRF connections through 10/100/1000BASE-T autosensing Ethernet ports and GE SFP ports.
  • Page 32: Planning The Cabling Scheme

    Table4-1 IRF physical ports and use restrictions Candidate IRF physical Chassis Use restrictions ports S3100V3-10TP-EI S3100V3-18TP-EI Only GE IRF connections are supported. S3100V3-18TP-EI-DC For a 52-port switch model, the 20 GE ports are divided into the following groups: S3100V3-28TP-EI All the 10/100/1000BASE-T •...
  • Page 33 Figure4-4 Connecting the switches in one rack Figure4-5 IRF fabric topology Connecting the IRF member switches in a ToR solution You can install IRF member switches in different racks side by side to deploy a top of rack (ToR) solution. Figure4-6 shows an example for connecting four top of rack IRF member switches by using SFP transceiver modules and optical fibers.
  • Page 34: Configuring Basic Irf Settings

    Wear an ESD wrist strap when you connect twisted pair cables, SFP cables, or SFP transceiver modules and fibers. For how to connect them, see H3C Transceiver Modules and Network Cables Installation Guide. Verifying the IRF fabric setup...
  • Page 35: Maintenance And Troubleshooting

    Verify that the operating temperature of the switch is in the acceptable range, and the power module has good ventilation. Over-temperature can cause the power module to stop working and enter the protection state. If the issue persists, contact H3C Support. DC input failure Symptom...
  • Page 36: Concurrent Dc And Ac Inputs Failure

    Verify that the operating temperature of the switch is in the acceptable range, and the power module has good ventilation. Over-temperature can cause the power module to stop working and enter the protection state. If the issue persists, contact H3C Support. Concurrent DC and AC inputs failure Symptom 1 The system status LED is off.
  • Page 37: Solution

    Solution When a fan tray issue occurs, contact H3C Support. Configuration terminal issues No display on the configuration terminal Symptom The configuration terminal does not have display when the switch is powered on. Solution To resolve the issue: Verify that the power system is operating correctly.
  • Page 38 Contents 1 Product models and technical specifications ············································ 2-2 Product models ··············································································································································· 2-2 Technical specifications ·································································································································· 2-3 Non-PoE switch models ·························································································································· 2-3 PoE switch models ·································································································································· 2-4 2 Chassis views ·························································································· 2-7 S3100V3-10TP-EI ··································································································································· 2-7 S3100V3-18TP-EI ··································································································································· 2-7 S3100V3-18TP-EI-DC ····························································································································· 2-8 S3100V3-28TP-EI ···································································································································...
  • Page 39: Product Models And Technical Specifications

    Product models and technical specifications Product models This document is applicable to the S3100V3-EI switch series. Table1-1 describes the S3100V3-EI switch series models. Table1-1 S3100V3-EI switch series models Switch model Product code (PID) LS-3100V3-10TP-EI S3100V3-10TP-EI LS-3100V3-10TP-EI-GL LS-3100V3-18TP-EI S3100V3-18TP-EI LS-3100V3-18TP-EI-GL S3100V3-18TP-EI-DC LS-S3100V3-18TP-EI-DC LS-3100V3-28TP-EI S3100V3-28TP-EI...
  • Page 40: Technical Specifications

    Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz  • Input voltage DC input from a –48 VDC power source in the equipment room or an H3C RPS1600-A (supported only by the S3100V3-18TP-EI-DC switch) Rated voltage: –48 VDC to –60 VDC ...
  • Page 41: Poe Switch Models

    Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz • Input voltage DC input from a –48 VDC power source in the equipment room or an H3C RPS1600-A (supported only by the S3100V3-28TP-EI-DC switch) Rated voltage: –48 VDC to –60 VDC ...
  • Page 42 Single DC input: –44 VDC to –60 VDC AC and DC inputs: –54 VDC to –57 VDC • DC input from a DC power supply system or an H3C RPS1600-A (supported only by an S3100V3-20TP-PWR-EI-DC switch): Rated voltage: –52 VDC to –57 VDC ...
  • Page 43 S3100V3-10TP- S3100V3-20TP-P S3100V3-20TP-P S3100V3-28TP-P Item PWR-EI WR-EI WR-EI-DC WR-EI system without fan trays to draw ambient air in to draw ambient air in trays to draw from the left side and from the left side and ambient air in from exhaust heated air exhaust heated air the left side and the...
  • Page 44: Chassis Views

    Chassis views S3100V3-10TP-EI Figure2-1 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) 10/100/1000BASE-T autosensing Ethernet port LED (7) Console port (8) SFP port Figure2-2 Rear panel (1) Grounding screw...
  • Page 45: S3100V3-18Tp-Ei-Dc

    (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (5) SFP port LED (6) System status LED (SYS) (7) Console port (8) SFP port Figure2-4 Rear panel (1) Grounding screw (2) AC-input power receptacle S3100V3-18TP-EI-DC Figure2-5 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) 10/100/1000BASE-T autosensing Ethernet port LED...
  • Page 46: S3100V3-28Tp-Ei

    S3100V3-28TP-EI Figure2-7 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) SFP port LED (6) System status LED (SYS) (7) Console port (8) SFP port Figure2-8 Rear panel (1) Grounding screw (2) AC-input power receptacle...
  • Page 47: S3100V3-52Tp-Ei

    Figure2-10 Rear panel (1) Grounding screw (2) DC-input power receptacle S3100V3-52TP-EI Figure2-11 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100BASE-T autosensing Ethernet port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Console port (6) System status LED (SYS) (7) SFP port (8) SFP port LED Figure2-12 Rear panel...
  • Page 48: S3100V3-10Tp-Pwr-Ei

    S3100V3-10TP-PWR-EI Figure2-13 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) 10/100/1000BASE-T autosensing Ethernet port LED (8) Port LED mode switching button (9) Console port (10) SFP port Figure2-14 Rear panel...
  • Page 49: S3100V3-20Tp-Pwr-Ei-Dc

    Figure2-16 Rear panel (1) AC-input power receptacle (2) Grounding screw S3100V3-20TP-PWR-EI-DC Figure2-17 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) SFP port LED (6) System status LED (SYS) (7) Mode LED (MODE) (8) Port LED mode switching button...
  • Page 50: S3100V3-28Tp-Pwr-Ei

    S3100V3-28TP-PWR-EI Figure2-19 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) System status LED (SYS) (5) RPS status LED (RPS) (6) Mode LED (MODE) (7) SFP port LED (8) 10/100/1000BASE-T autosensing Ethernet port LED (9) Port LED mode switching button (10) Console port (11) SFP port...
  • Page 51: Ports And Leds

    Ports and LEDs Ports Console port Table3-1 Console port specifications Item Specification Connector type RJ-45 Compliant standard EIA/TIA-232 Transmission baud rate 9600 bps (default) to 115200 bps • Provides connection to an ASCII terminal. • Services Provides connection to the serial port of a local PC running terminal emulation program.
  • Page 52: Sfp Port

    Item Specification distance Transmission medium Category-5 (or above) twisted pair cable • IEEE 802.3i • 802.3u Compatible standards • 802.3ab SFP port The S3100V3-EI switches provide SFP ports. SFP transceiver modules and cables available for the SFP ports vary by switch model, as shown in Table3-4. Table3-4 SFP transceiver modules and cables available for the switches Available SFP transceiver Switch model...
  • Page 53 GE SFP Central Cable/Fiber Modal Connect transceiver wavelength type and bandwidth transmission module and (nm) diameter (µm) (MHz × km) distance cable M850-D 50/125 500 m (1640.42 ft) 275 m (902.23 ft) Multi-mode, 62.5/125 220 m (721.78 ft) 550 m (1804.46 ft) Multi-mode, 50/125 500 m (1640.42 ft)
  • Page 54 • As a best practice, use H3C SFP transceiver modules and cables for the SFP ports. • The H3C SFP transceiver modules and cables available for the SFP ports are subject to change over time. For the most up-to-date list of H3C SFP transceiver modules and cables available for the SFP ports, contact your H3C sales representative or technical support engineer.
  • Page 55: Combo Interface

    Combo interface The S3100V3-28TP-PWR-EI switch provides four combo interfaces. Each combo interface contains an SFP port and a 10/100/1000BASE-T autosensing Ethernet port. Only one of these two ports can operate at a time. LEDs System status LED The system status LED shows the operating status of the switch. Table3-7 System status LED description LED mark Status...
  • Page 56: Sfp Port Led

    LED mark Status Description Flashing green (available The autosensing Ethernet port LEDs are showing the PoE only for PoE switches) status of the ports. The autosensing Ethernet port LEDs work in conjunction to indicate the IRF member ID of the switch. For example, if the Flashing yellow LED for port 5 is steady green, the IRF member ID of the switch is 5.
  • Page 57 • The S3100V3-EI non-PoE switches do not have a mode LED. Table3-12 describes the 10/100BASE-T and 10/100/1000BASE-T autosensing Ethernet ports LEDs on these switches. Table3-12 10/100BASE-T and 10/100/1000BASE-T autosensing Ethernet port LED description LED status Description Steady green A link is present on the port. Flashing green The port is sending or receiving data.

Table of Contents