Ead Configuration Example - H3C S3100 8C SI Operation Manual

S3100 series ethernet switches
Table of Contents

Advertisement

Operation Manual – AAA
H3C S3100 Series Ethernet Switches
Table 3-1 EAD configuration
Enter system view
Enter RADIUS scheme
view
Configure the RADIUS
server type to extended
Configure the IP address
of a security policy server

3.4 EAD Configuration Example

I. Network requirements
In
Figure
A user is connected to Ethernet 1/0/1 on the switch.
The user adopts 802.1x client supporting EAD extended function.
You are required to configure the switch to use RADIUS server for remote user
authentication and use security policy server for EAD control on users.
The following are the configuration tasks:
Connect the RADIUS authentication server 10.110.91.164 and the switch, and
configure the switch to use port number 1812 to communicate with the server.
Configure the authentication server type to extended.
Configure the encryption password for exchanging messages between the switch
and RADIUS server to "expert".
Configure the IP address 10.110.91.166 of the security policy server.
Operation
system-view
radius scheme
radius-scheme-name
server-type extended
security-policy-server
ip-address
3-2:
Command
3-3
Chapter 3 EAD Configuration
Remarks
Required
Required
Each RADIUS scheme
supports up to eight IP
addresses of security
policy servers.