2.1 Basic System Configuration

Table 2-1 Basic System Configuration
Operation
Set the current date
and time of the
system
Set the local time
zone
Set the name and
time range of the
summer time
Enter system view
from user view
Set the system
name of the switch
Return from current
view to lower level
view
Debugging
Command
clock datetime
HH:MM:SS
{ YYYY/MM/DD |
MM/DD/YYYY }
clock timezone
zone-name { add |
minus } HH:MM:SS
clock summer-time
zone_name { one-off |
repeating } start-time
start-date end-time
end-date offset-time
system-view
sysname sysname
quit
2-1
Chapter 2 Basic System Configuration
and Debugging
Description
Required
Execute this command in user
view.
The default value is 23:55:00
04/01/2000 when the system
starts up.
Optional
Execute this command in user
view.
By default, it is the UTC time
zone.
Optional
Execute this command in user
view.
When the system reaches the
specified
start
automatically
adds
specified offset to the current
time, so as to toggle the
system time to the summer
time.
When the system reaches the
specified
end
automatically subtracts the
specified
offset
current time, so as to toggle
the summer time to normal
system time.
Optional
By default, the name is H3C.
Optional
If the current view is user view,
you will quit the current user
interface.
time,
it
the
time,
it
from
the