Hwping Client Configuration - H3C S3100 8C SI Operation Manual

S3100 series ethernet switches
Table of Contents

Advertisement

Operation Manual – HWPing
H3C S3100 Series Ethernet Switches
Table 1-4 HWPing server configuration
Enter system view
Enable the HWPing
server function
Configure a UDP listening
service
Configure a TCP listening
service

1.2.2 HWPing Client Configuration

I. HWPing client configuration
After HWPing client is enabled, you can create multiple test groups for different tests,
without the need to enable HWPing client repeatedly for each test group.
Different types of HWPing tests are somewhat different in parameters and parameter
ranges. The following text describes the configuration on HWPing client for different
test types.
1)
Configuring ICMP test on HWPing client
Table 1-5 Configure ICMP test on HWPing client
Enter system view
Enable the HWPing client
function
Create a HWPing test
group and enter its view
Configure the test type
Configure the destination
IP address
Operation
system-view
hwping-server enable
hwping-server udpecho
ip-address port-num
hwping-server
tcpconnect ip-address
port-num
Operation
system-view
hwping-agent enable
hwping
administrator-name
operation-tag
test-type icmp
destination-ip ip-address
Chapter 1 HWPing Configuration
Command
Command
1-6
Description
Required
Disabled by default.
Required for UDP and
jitter tests
By default, no UDP
listening service is
configured.
Required for TCP tests
By default, no TCP
listening service is
configured.
Description
Required
By default, the HWPing
client function is disabled.
Required
By default, no test group
is configured.
Optional
By default, the test type is
ICMP.
Required
By default, no destination
address is configured.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H3C S3100 8C SI and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

S3100-si seriesS3100-ei series

Table of Contents