Page 1
H3C S5560S-SI & S5500V3-SI & S5130S-SI[LI] S5120V2-SI[LI] & & S5110V2-SI & S5000V3-EI & S5000V5-EI & S3100V3-SI Switch Series Installation Guide H3C S5560S-SI Switch Series H3C S5500V3-SI Switch Series H3C S5130S-SI Switch Series H3C S5130S-LI Switch Series H3C S5120V2-SI Switch Series...
Page 2
The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
Page 3
Preface The installation guide describes the appearance, installation, power-on, maintenance, and troubleshooting of the H3C S5560S-SI, S5500V3-SI, S5130S-SI, S5130S-LI, S5120V2-SI, S5120V2-LI, S5110V2-SI, S5000V3-EI, S5000V5-EI, and S3100V3-SI Switch Series. This preface includes the following topics about the documentation: • Audience. •...
Page 4
Convention Description Multi-level menus are separated by angle brackets. For example, File > Create > > Folder. Symbols Convention Description An alert that calls attention to important information that if not understood or followed WARNING! can result in personal injury. An alert that calls attention to important information that if not understood or followed CAUTION: can result in data loss, data corruption, or damage to hardware or software.
Page 5
It is normal that the port numbers, sample output, screenshots, and other information in the examples differ from what you have on your device. Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
Contents 1 Preparing for installation ·········································································· 1-1 Safety recommendations ································································································································ 1-4 Examining the installation site ························································································································· 1-4 Temperature/humidity ····························································································································· 1-4 Cleanliness ·············································································································································· 1-5 Corrosive gas limit ··································································································································· 1-5 EMI ·························································································································································· 1-6 Laser safety ············································································································································· 1-7 Installation tools ·············································································································································· 1-7 2 Installing the switch ·················································································· 2-8 Installing the switch in a 19-inch rack··············································································································...
Page 7
Input failure on an AC-powered switch ································································································· 5-45 Input failure on a DC-powered switch ··································································································· 5-46 Input failure on a DC and AC-powered switch ······················································································ 5-46 Removable power supply failure ··················································································································· 5-47 Fan tray failure ·············································································································································· 5-47 Configuration terminal issues ························································································································ 5-47 No display on the configuration terminal ·······························································································...
Preparing for installation This document provides an installation guide for the following switch series: • S5560S-SI switch series • S5130S-SI switch series • S5130S-LI switch series • S5120V2-SI switch series • S5120V2-LI switch series • S5110V2-SI switch series • S5000V3-EI switch series •...
Safety recommendations To avoid equipment damage or bodily injury, read the following safety recommendations before installation. Note that the recommendations do not cover every possible hazardous condition. • Before cleaning the switch, remove all power cords from the switch. Do not clean the switch with wet cloth or liquid.
Cleanliness Dust buildup on the chassis might cause electrostatic adsorption and dust corrosion, resulting in poor contact of metal connectors and contact points. This might shorten the device's lifetime and even cause device failure in the worst case. Table1-2 describes the dust concentration limits in the equipment room for the S5560S-SI and S5500V3-SI switch series.
Average concentration (mg/m Maximum concentration (mg/m 0.01 0.03 0.05 CAUTION: As a best practice, control the corrosive gas concentrations in the equipment room at their average values. Make sure the corrosive gas concentrations do not exceed 30 minutes per day at their maximum values.
Laser safety WARNING! Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare into beams or view directly with optical instruments when the switch is operating. The switch is Class 1 laser device. Installation tools No installation tools are provided with the switch. Prepare them yourself as required. •...
CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence. Figure2-1 Hardware installation flow Start...
Installing the switch in a 19-inch rack Mounting brackets Table2-2 describes the mounting brackets applicable to the switch. Table2-2 Mounting brackets applicable to the switch Applicable mounting Switch model Views brackets S5560S-28P-SI S5560S-52P-SI S5560S-28S-SI S5560S-52S-SI S5130S-28S-SI S5130S-28S-SI-MM S5130S-28S-SI-SM S5130S-52S-SI S5130S-28S-LI S5130S-28S-LI-MM S5130S-28S-LI-SM S5130S-52S-LI...
Page 17
Applicable mounting Switch model Views brackets S3100V3-28TP-SI S3100V3-52TP-SI S3100V3-28TP-PWR-SI S5560S-28F-SI S5560S-28DP-SI S5500V3-28S-SI S5500V3-28PS-SI S5500V3-54S-SI S5500V3-54PS-SI Mounting brackets B (provided) See B in Figure2-2. S5500V3-36F-SI S5500V3-28S-DP-SI S5500V3-54S-DP-SI S5500V3-36F-DP-SI S5500V3-54F-DP-SI S5130S-28F-SI S5120V2-20P-LI S5120V2-10P-PWR-LI S5120V2-12TP-HPWR-LI Mounting brackets C with S5008PV5-EI-HPWR product code See C in Figure2-2. SOHO-SWITCH-FL-02 S5016PV3-EI (optional)
Figure2-2 Mounting brackets (1) Screw hole for attaching the bracket to the switch (2 ) Screw hole for attaching the bracket to the rack post Attaching the mounting brackets to the switch Determine the installation position for the mounting brackets. The S5560S-28F-SI, S5560S-28DP-SI, S5500V3-28S-DP-SI, S5500V3-54S-DP-SI, ...
Page 19
Figure2-3 Attaching mounting bracket A (S5120V2-28P-HPWR-LI switch) Figure2-4 Attaching mounting bracket B (mounting position near the port side, S5560S-28F-SI switch) Figure2-5 Attaching mounting bracket B (mounting position near the power supply side, S5560S-28F-SI switch) 2-12...
Figure2-6 Attaching mounting bracket C (S5120V2-20P-LI switch) Figure2-7 Attaching mounting bracket D (S5120V2-10P-LI switch) Rack-mounting the switch This task requires two people. To mount the switch in the rack: Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Verify that the mounting brackets have been securely attached to the switch chassis.
Page 21
Figure2-8 Mounting the switch in a rack (S5120V2-28P-HPWR-LI switch) Figure2-9 Mounting the switch in a rack (mounting brackets installed near the port side, S5560S-28F-SI switch) Figure2-10 Mounting the switch in a rack (mounting brackets installed near the power supply side, S5560S-28F-SI switch) 2-14...
Figure2-11 Mounting the switch in a rack (S5120V2-10P-PWR-LI switch) Figure2-12 Mounting the switch in a rack (S5120V2-10P-LI) Mounting the switch on a workbench IMPORTANT: • Ensure 10 cm (3.9 in) of clearance around the chassis for heat dissipation. • Do not place heavy objects on the switch. If a standard 19-inch rack is not available, you can place your switch on a workbench.
Mounting the switch on a wall CAUTION: • Before drilling holes in a wall, make sure no electrical lines exist in the wall. • Leave a minimum clearance of 10 mm (0.39 in) around the chassis for heat dissipation. The S5120V2-SI, S5120V2-LI, S5000V3-EI, S5000V5-EI, and S3100V3-SI switch series support wall mounting.
Page 24
Figure2-14 Installing the switch on a wall (1) Drill two holes with a diameter of 6 mm (0.24 in) and a depth of 25 mm (0.98 in) at the marked locations. Hammer the screw anchors into the wall and use a Phillips screwdriver to fasten the screw into the screw anchor.
Grounding the switch WARNING! Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection. The power input end of the switch has a noise filter, whose central ground is directly connected to the chassis to form the chassis ground (commonly known as PGND). You must securely connect this chassis ground to the earth to minimize the potential for system damage, maximize the safety at the site, and minimize EMI susceptibility of the system.
Figure2-17 Attaching the grounding cable to the grounding hole of the switch (S5120V2-28P-HPWR-LI switch) (1) Grounding screw (2) Ring terminal (3) Grounding sign (4) Grounding hole (5) Grounding cable Connect the other end of the grounding cable to the grounding strip. a.
Weld the yellow-green grounding cable to the angel iron or steel tube and treat the joint for corrosion protection. Figure2-19 Grounding the switch by burying the grounding conductor into the earth ground (1) Grounding screw (2) Grounding cable (3) Earth (4) Joint (5) Grounding conductor (6) Chassis rear panel...
This section is applicable only to the switch models that use removable power supplies. For the switch models that use removable power supplies and the available power supplies, see hardware information and specifications for the switches. Figure2-20 Installation procedure Install the power Connect the power Turn on the circuit supply...
Figure2-23 Installing a power supply Removing a power supply Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Remove the power cord from the power supply. Use a Phillips screwdriver to loosen the captive screws on the power supply until they are completely disengaged from the chassis.
Table2-4 Power cord connection procedures at a glance Connection procedure Switch model Available power source reference S5130S-28S-HPWR-LI Connecting the AC power cord for AC power source the fixed AC power supply S5130S-52S-PWR-LI S5120V2-28P-HPWR-LI S5120V2-52P-PWR-LI Connecting the DC power cord for S5048PV3-EI-PWR RPS (RPS1600-A) the fixed DC power supply...
Connecting the DC power cord for the fixed DC power supply CAUTION: To connect to an H3C recommended RPS, use a power cord compatible with the RPS. To connect the DC power cord for the fixed DC power supply: Correctly orient the DC power cord connector and insert the connector into the power receptacle on the power supply.
Connecting the power cord for a CA-70A12 or PSR75-12A power supply The power cord connection procedure is similar for the CA-70A12 and PSR75-12A power supplies. The following procedure connects the power cord for a PSR75-12A power supply. To connect the power cord for a PSR75-12A power supply: Wear an ESD wrist strap.
To ensure correct connections, identify the positive and negative marks on the power wires before connecting them. • To connect the power cord to an H3C RPS, use a power cord matching the RPS. To connect the DC power cord for a PSR150-D1 power supply: Wear an ESD wrist strap.
Page 34
• If a power line is routed from outdoors, verify that a surge protected power strip is used for the switch. 2-27...
Accessing the switch for the first time You can use the following methods to access and manage the switch for the first time: • Managing the switch from the GUI • Managing the switch from the CLI Managing the switch from the GUI Only the S5000V3-EI switch series and S5000V5-EI switch series (except the S5008PV5-EI and S5008PV5-EI-HPWR switches) support GUI management.
As a best practice, use a serial console cable for connection. No serial console cable or micro USB console cable is provided with the switch. Purchase a serial console cable from H3C or prepare a micro USB console cable yourself. Table3-1 Connection methods by using different console cables...
Connecting a console cable Connecting a DB9-to-RJ45 console cable A DB9-to-RJ45 console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the serial console port of the switch, and a DB-9 female connector at the other end for connecting to the serial port on the configuration terminal.
Page 38
Click the following link, or copy it to the address bar on your browser and download the USB-to-RJ45 console driver. http://www.h3c.com/en/home/USB_to_RJ45_Console/ View the TXT file Read me in the Windows folder to check whether the Windows system of the configuration terminal supports the driver.
Page 39
Figure3-4 Driver installation wizard Click Finish after the drive installation is completed. Figure3-5 Finishing the driver installation Connect the standard USB connector of the cable to the USB port of the configuration terminal. 3-32...
Connect the micro USB connector to the micro USB console port on the switch. Click the following link, or copy it to the address bar on the browser to download the USB console driver. http://www.h3c.com/en/home/USB_Console/ Select a driver program according to the operating system you use: XR21V1410_XR21B1411_Windows_Ver1840_x86_Installer.EXE—32-bit operating ...
Page 41
Figure3-7 Device Driver Installation Wizard Click Continue Anyway if the following dialog box appears. Figure3-8 Software Installation Click Finish. 3-34...
Figure3-9 Completing the device driver installation wizard Setting terminal parameters To configure and manage the switch through the console port, you must run a terminal emulator program, such as TeraTermPro, on your configuration terminal. You can use the emulator program to connect a network device, a Telnet site, or an SSH site.
Page 43
Powering on the switch During the startup process, you can access Boot ROM menus to perform tasks such as software upgrade and file management. The Boot ROM interface and menu options differ with software versions. For more information about Boot ROM menu options, see the software-matching release notes for the device.
The S5008PV5-EI and S5008PV5-EI-HPWR switches do not support IRF, so this section is not applicable to the S5008PV5-EI and S5008PV5-EI-HPWR switches. You can use H3C IRF technology to connect and virtualize multiple switches into a large virtual switch called an "IRF fabric" for flattened network topology, and high availability, scalability, and manageability.
IRF fabric setup flowchart Figure4-1 IRF fabric setup flowchart Start Plan IRF fabric setup Install IRF member switches Connect the grounding cables and power cords Power on the switches Configure basic IRF settings Connect the physical IRF ports Subordinate switches reboot and the IRF fabric is automatically established To set up an IRF fabric:...
Step Description Connect IRF physical ports on switches. For long-distance connection, use SFP/SFP+ transceiver modules and optical fibers. For short-distance connection, use twisted-pair cables or Connect the IRF physical ports. SFP/SFP+ cables. All switches except the master switch automatically reboot, and the IRF fabric is established.
NOTE: The following figures use the SFP+ ports on S5120V2-28P-HPWR-LI switches as an example. For the ports that can be used for IRF connections, see Table4-1. Figure4-2 IRF fabric in daisy chain topology IRF-port1 IRF-port1 IRF-port2 IRF-port2 Figure4-3 IRF fabric in ring topology IRF-port1 IRF-port2 IRF-port2...
Page 48
Table4-2 IRF physical ports and use restrictions Chassis Candidate IRF physical ports Use restrictions S5560S-28S-SI S5130S-28S-SI S5130S-28S-SI-MM S5130S-28S-SI-SM The physical ports bound to an IRF port S5130S-28S-LI must operate at the same speed. S5130S-28S-LI-MM • 10/100/1000BASE-T autosensing S5130S-28S-LI-SM port—1 Gbps •...
If the IRF member switches are all in one equipment room, use twisted pair cables or SFP/SFP+ cables. The following subsections describe several H3C recommended IRF connection schemes by using SFP cables and SFP transceiver modules and fibers. All these schemes use a ring topology.
IRF member switches as planned. Wear an ESD wrist strap when you connect twisted pair cables, SFP/SFP+ cables, or SFP/SFP+ transceiver modules and fibers. For how to connect them, see H3C Transceiver Modules and Network Cables Installation Guide. 4-43...
Verifying the IRF fabric setup To verify the basic functionality of the IRF fabric after you finish configuring basic IRF settings and connecting IRF ports: Log in to the IRF fabric through the console port of any member switch. Create a Layer 3 interface, assign it an IP address, and make sure the IRF fabric and the remote network management station can reach each other.
Maintenance and troubleshooting Fixed power supply failure The following switch series uses fixed power supplies: • S5560S-SI switch series (except the S5560S-28F-SI) • S5130S-SI switch series (except the S5130S-28F-SI) • S5130S-LI switch series • S5120V2-SI switch series • S5120V2-LI switch series •...
Verify that the operating temperature of the switch is in the acceptable range, and the power supply has good ventilation. Over-temperature can cause the power supply to stop working and enter protection state. If the issue persists, contact H3C Support. Input failure on a DC-powered switch Symptom The system status LED on the DC-powered switch is off.
Fan tray failure Symptom The system status LED on the switch indicates a fan tray failure. Solution When a fan tray issue occurs, contact H3C Support. Configuration terminal issues No display on the configuration terminal Symptom The configuration terminal does not have display when the switch is powered on.
Stop bits—1. Flow control—None. Verify that the console cable is not faulty. If the issue persists, contact H3C Support. Garbled display on the configuration terminal Symptom The configuration terminal displays garbled text. Solution To resolve the issue: Verify that the following settings are configured for the terminal: Baud rate—9600.
Page 56
Contents 1 Product models and technical specifications ············································ 1-3 Product models ··············································································································································· 1-3 Technical specifications ·································································································································· 1-6 S5560S-SI switch series ························································································································· 1-6 S5500V3-SI switch series ······················································································································· 1-8 S5130S-SI & S5130S-LI switch series ·································································································· 1-11 S5120V2-SI & S5120V2-LI switch series ······························································································ 1-14 S5110V2-SI switch series ·····················································································································...
Product models and technical specifications Product models This document provides an installation guide for the following switch series: • S5560S-SI switch series • S5500V3-SI switch series • S5130S-SI switch series • S5130S-LI switch series • S5120V2-SI switch series • S5120V2-LI switch series •...
Item S5560S-28F-SI S5560S-28DP-SI Fire resistance UL 62368-1/EN 62368-1/IEC 62368-1/UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1 compliance S5500V3-SI switch series Table1-4 Technical specifications for S5500V3-SI switch models (1) Item S5500V3-24P-SI S5500V3-48P-SI S5500V3-28S-SI S5500V3-28PS-SI 43.6 × 440 × 160 43.6 × 440 × 230 mm 43.6 ×...
Page 64
Item S5500V3-24P-SI S5500V3-48P-SI S5500V3-28S-SI S5500V3-28PS-SI Operating –5°C to +45°C (23°F to 113°F) temperature Operating 5% RH to 95% RH, noncondensing humidity Fire resistance UL 62368-1/EN 62368-1/IEC 62368-1/UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1 compliance Table1-5 Technical specifications for S5500V3-SI switch models (2) Item S5500V3-54S-SI S5500V3-54PS-SI S5500V3-36F-SI...
Page 65
Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz Input voltage • Max voltage: 90 VAC to 290 VAC @ 47 to 63 Hz PSR150-D1 power supply (–48 VDC power source in the equipment room or an H3C RPS1600-A): • Rated voltage: –48 VDC to –60 VDC •...
S5500V3-28S-D S5500V3-54S-DP- S5500V3-36F-D S5500V3-54F-DP- Item P-SI P-SI • Melting CA-70A12 power supply: 10 A/250 V current of • PSR75-12A power supply: 3.15 A/250 V power supply • PSR150-D1 power supply: 8 A/250 V fuse Cooling Left-right air aisle, intaking cool air from the chassis left side and exhausting hot air from the system chassis right side Operating...
Page 67
S5130S-28S-SI S5130S-28S-SI-MM S5130S-28S-SI-SM S5130S-52S-SI Item S5130S-28F-SI S5130S-28S-LI S5130S-52S-LI S5130S-28S-LI-MM S5130S-28S-LI-SM • AC input Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz Max voltage range: 90 • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz VAC to 290 VAC @ 47 Input voltage •...
Page 68
Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz • Max voltage range: 90 VAC to 264 VAC @ 47 Hz to 63 Hz H3C RPS1600-A DC input (only for the S5130S-52S-PWR-LI and S5130S-28S-HPWR-LI): Input voltage •...
Item S5130S-28S-PWR-LI S5130S-52S-PWR-LI S5130S-28S-HPWR-LI Operating 5% RH to 95% RH, noncondensing humidity Fire resistance UL 62368-1/EN 62368-1/IEC 62368-1/UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1 compliance S5120V2-SI & S5120V2-LI switch series Table1-9 Technical specifications for the S5120V2-SI & S5120V2-LI non-PoE switch models S5120V2-10P-SI S5120V2-28P-SI S5120V2-52P- SI Item S5120V2-20P-LI...
Page 70
• Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz H3C RPS1600-A DC input (only for the S5120V2-28P-HPWR-LI and S5120V2-52P-PWR-LI Input switches): voltage •...
S5120V2-10P- S5120V2-28P- S5120V2-52P- S5120V2-28P- S5120V2-12 Item PWR-LI PWR-LI PWR-LI HPWR-LI TP-HPWR-LI not support PoE do not support power supply. PoE power supply. AC: 370 W AC: 370 W Total PoE 125 W 170 W 125 W power DC: 740 W DC: 740 W Minimum AC: 36 W...
Item S5110V2-28P-SI S5110V2-52P-SI Console port 1 × serial console port 1 × serial console port 10/100/1000BASE- T autosensing Ethernet port SFP port • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz Input voltage • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz Minimum power 18 W consumption...
Page 73
Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz Input voltage H3C RPS1600-A DC input (only for the S5024PV3-EI-HPWR and S5048PV3-EI-PWR switches): • Rated voltage: –54 VDC to –57 VDC...
Item S5024PV3-EI-PWR S5024PV3-EI-HPWR S5048PV3-EI-PWR • Max voltage: Single DC input: –44 VDC to –60 VDC AC and DC inputs: –54 VDC to –57 VDC Maximum PoE power 30 W 30 W 30 W per port AC: 370 W AC: 370 W Total PoE 170 W...
Page 75
Item S5008PV5-EI S5016PV5-EI S5024PV5-EI S5048PV5-EI Ethernet port SFP port • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz Input voltage • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz Minimum power 18 W consumption Maximum 12 W...
S5008PV5-EI-H S5024PV5-EI-PW S5024PV5-EI-HP Item S5048PV5-EI-PWR • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz Maximum PoE power 30 W 30 W 30 W 30 W per port Total PoE 125 W 240 W 370 W 370 W power Minimum power...
Page 77
Item S3100V3-10TP-SI S3100V3-18TP-SI S3100V3-28TP-SI S3100V3-52TP-SI Ethernet port 10/100/1000 BASE-T autosensing Ethernet port SFP port • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz Input voltage • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz Minimum power 6.5 W...
Page 78
Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz H3C RPS1600-A DC input (only for an S3100V3-28TP-PWR-SI switch): Input voltage • Rated voltage: –54 VDC to –57 VDC •...
Chassis views S5560S-SI switch series S5560S-28P-SI Figure2-1 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-2 Rear panel (1) Grounding screw (2) AC-input power receptacle 2-24...
S5560S-52P-SI Figure2-3 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) SFP port LED (5) System status LED (SYS) (6) SFP port Figure2-4 Rear panel (1) Grounding screw (2) AC-input power receptacle S5560S-28S-SI Figure2-5 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
Figure2-6 Rear panel (1) Grounding screw (2) AC-input power receptacle S5560S-52S-SI Figure2-7 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) Micro USB console port (5) SFP+ port LED (6) System status LED (SYS) (7) SFP+ port Figure2-8 Rear panel (1) Grounding screw...
S5560S-28F-SI Figure2-9 Front panel (1) SFP port (2) SFP port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Management Ethernet port (6) Console port (CONSOLE) (7) Micro USB console port (8) System status LED (SYS) (9) Power supply 2 status LED (PWR2) (10) Power supply 1 status LED (PWR1) (11) SFP+ port LED...
S5560S-28DP-SI Figure2-11 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Management Ethernet port (4) Console port (CONSOLE) (5) Micro USB console port (6) Mode button (7) Mode LED (MODE) (8) USB port (9) System status LED (SYS) (10) SFP port (11) Power supply 2 status LED (PWR2) (12) Power supply 1 status LED (PWR1)
S5500V3-SI switch series S5500V3-24P-SI Figure2-13 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP+ port LED (4) System status LED (SYS) (5) SFP port LED (6) Micro USB console port (7) Console port (CONSOLE) (8) SFP+ port (9) SFP port Figure2-14 Rear panel...
(5) Micro USB console port (6) SFP+ port LED (7) System status LED (SYS) (8) SFP+ port (9) SFP port Figure2-16 Rear panel (1) Grounding screw (2) AC-input power receptacle S5500V3-28S-SI Figure2-17 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) SFP+ port (3) Console port (CONSOLE) (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) System status LED (SYS)
S5500V3-28PS-SI Figure2-19 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) SFP port (3) SFP+ port (4) Console port (CONSOLE) (5) 10/100/1000BASE-T autosensing Ethernet port LED (6) SFP port LED (7) System status LED (SYS) (8) SFP+ port LED Figure2-20 Rear panel (1) Grounding screw (2) AC-input power receptacle S5500V3-54S-SI...
Figure2-22 Rear panel (1) AC-input power receptacle (2) Grounding screw S5500V3-54PS-SI Figure2-23 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) SFP+ port LED (5) Console port (CONSOLE) (6) System status LED (SYS) (7) SFP+ port (8) SFP port Figure2-24 Rear panel...
S5500V3-36F-SI Figure2-25 Front panel (1) 1000BASE-X SFP port (2) 10/100/1000BASE-T autosensing Ethernet port (3) SFP+ port (4) Console port (CONSOLE) (5) 1000BASE-X SFP port LED (6) 10/100/1000BASE-T autosensing Ethernet port LED (7) System status LED (SYS) (8) SFP+ port LED Figure2-26 Rear panel (1) AC-input power receptacle (2) Grounding screw...
(9) SFP+ port LED (10) Mode button Figure2-28 Rear panel (1) Grounding screw (2) Power supply 1 (3) Power supply 2 The S5500V3-28S-DP-SI switch provides two power supply slots and comes with power supply slot 1 installed with a CA-70A12 power supply and power supply slot 2 installed with a filler panel. As shown in Figure2-28, two CA-70A12 power supplies are installed in the S5500V3-28S-DP-SI switch.
(3) Power supply 2 The S5500V3-54S-DP-SI switch provides two power supply slots and comes with power supply slot 1 installed with a CA-70A12 power supply and power supply slot 2 installed with a filler panel. As shown in Figure2-30, two CA-70A12 power supplies are installed in the S5500V3-54S-DP-SI switch. S5500V3-36F-DP-SI Figure2-31 Front panel (1) 1000BASE-X SFP port...
S5500V3-54F-DP-SI Figure2-33 Front panel (1) 1000BASE-X SFP port (2) 1000BASE-X SFP port LED (3) SFP+ port (4) SFP+ port LED (5) Console port (CONSOLE) (6) Management Ethernet port (7) System status LED (SYS) (8) Management Ethernet port LED (9) Power supply 2 status LED (PWR2) (10) Power supply 1 status LED (PWR1) Figure2-34 Rear panel (1) Grounding screw...
S5130S-SI & S5130S-LI switch series S5130S-28S-SI & S5130S-28S-LI Figure2-35 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP+ port LED (4) System status LED (SYS) (5) Micro USB console port (6) Console port (CONSOLE) (7) SFP+ port Figure2-36 Rear panel (1) Grounding screw...
(1) 10/100/1000BASE-T autosensing Ethernet port (3) SFP+ port LED (4) System status LED (SYS) (5) Micro USB console port (6) Console port (CONSOLE) (7) 10GBASE-SX-FD-MM-SR port (8) SFP+ port NOTE: A 10-GE SFP+ transceiver module is built into the 10GBASE-SX-FD-MM-SR port on the S5130S-28S-SI-MM and S5130S-28S-LI-MM switches.
Figure2-40 Rear panel (1) Grounding screw (2) AC-input power receptacle S5130S-52S-SI & S5130S-52S-LI Figure2-41 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) Micro USB console port (5) SFP+ port LED (6) System status LED (SYS) (7) SFP+ port Figure2-42 Rear panel...
S5130S-28F-SI Figure2-43 Front panel (1) SFP port (2) SFP port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Management Ethernet port (6) Console port (CONSOLE) (7) Micro USB console port (8) System status LED (SYS) (9) Power supply 2 status LED (PWR2) (10) Power supply 1 status LED (PWR1) (11) SFP+ port LED...
S5130S-28S-PWR-LI Figure2-45 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP+ port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Micro USB console port (8) Console port (CONSOLE) (9) SFP+ port Figure2-46 Rear panel (1) Grounding screw...
Figure2-48 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle S5130S-52S-PWR-LI Figure2-49 Front panel 10 9 (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) Mode button (5) System status LED (SYS) (6) RPS status LED (RPS) (7) Mode LED (MODE) (8) Micro USB console port...
S5120V2-SI & S5120V2-LI switch series S5120V2-10P-SI & S5120V2-10P-LI Figure2-51 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-52 Rear panel (1) Grounding screw (2) AC-input power receptacle S5120V2-20P-LI...
Figure2-54 Rear panel (1) AC-input power receptacle (2) Grounding screw S5120V2-28P-SI & S5120V2-28P-LI Figure2-55 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-56 Rear panel (1) Grounding screw...
S5120V2-52P-SI & S5120V2-52P-LI Figure2-57 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) SFP port LED (5) System status LED (SYS) (6) SFP port Figure2-58 Rear panel (1) Grounding screw (2) AC-input power receptacle S5120V2-10P-PWR-LI Figure2-59 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
Figure2-60 Rear panel (1) AC-input power receptacle (2) Grounding screw S5120V2-28P-PWR-LI Figure2-61 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure2-62 Rear panel...
S5120V2-28P-HPWR-LI Figure2-63 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Console port (CONSOLE) (3) Mode button (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) System status LED (SYS) (6) RPS status LED (RPS) (7) Mode LED (MODE) (8) SFP port LED (9) SFP port Figure2-64 Rear panel (1) Grounding screw...
Figure2-66 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle S5120V2-12TP-HPWR-LI Figure2-67 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Mode LED (MODE) (6) Mode button (7) Console port (CONSOLE) (8) SFP port...
S5110V2-SI switch series S5110V2-28P-SI Figure2-69 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-70 Rear panel (1) Grounding screw (2) AC-input power receptacle S5110V2-52P-SI Figure2-71 Front panel...
Figure2-72 Rear panel (1) Grounding screw (2) AC-input power receptacle S5000V3-EI switch series S5016PV3-EI Figure2-73 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-74 Rear panel (1) AC-input power receptacle...
S5024PV3-EI Figure2-75 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-76 Rear panel (1) Grounding screw (2) AC-input power receptacle S5048PV3-EI Figure2-77 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
Figure2-78 Rear panel (1) Grounding screw (2) AC-input power receptacle S5024PV3-EI-PWR Figure2-79 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure2-80 Rear panel...
S5024PV3-EI-HPWR Figure2-81 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure2-82 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle...
Figure2-84 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle S5024FV3-EI Figure2-85 Front panel (1) SFP port (2) 10/100/1000BASE-T autosensing Ethernet port (3) SFP port LED (4) System status LED (SYS) (5) 10/100/1000BASE-T autosensing Ethernet port LED (6) Console port (CONSOLE) Figure2-86 Rear panel (1) AC-input power receptacle...
S5000V5-EI switch series S5008PV5-EI Figure2-87 Front panel (1) 10/100/1000BASE-T copper port (2) 100/1000BASE-X SFP port (3) Console port (CONSOLE) (4) Port status LED (5) Power status LED (Power) Figure2-88 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) Security slot S5016PV5-EI Figure2-89 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
Figure2-90 Rear panel (1) AC-input power receptacle (2) Grounding screw S5024PV5-EI Figure2-91 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure2-92 Rear panel (1) Grounding screw (2) AC-input power receptacle...
S5048PV5-EI Figure2-93 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) SFP port LED (5) System status LED (SYS) (6) SFP port Figure2-94 Rear panel (1) Grounding screw (2) AC-input power receptacle S5008PV5-EI-HPWR Figure2-95 Front panel (1) 10/100/1000BASE-T copper port...
S5024PV5-EI-PWR Figure2-97 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure2-98 Rear panel (1) Grounding screw (2) AC-input power receptacle S5024PV5-EI-HPWR...
Figure2-100 Rear panel (1) Grounding screw (2) AC-input power receptacle S5048PV5-EI-PWR Figure2-101 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) Mode button (5) System status LED (SYS) (6) Mode LED (MODE) (7) SFP port LED (8) SFP port Figure2-102 Rear panel...
S3100V3-SI switch series S3100V3-10TP-SI Figure2-103 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) 10/100/1000BASE-T autosensing Ethernet port LED (7) Console port (CONSOLE) (8) SFP port Figure2-104 Rear panel (1) Grounding screw...
Figure2-106 Rear panel (1) Grounding screw (2) AC-input power receptacle S3100V3-28TP-SI Figure2-107 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) SFP port LED (6) System status LED (SYS) (7) Console port (CONSOLE) (8) SFP port...
S3100V3-52TP-SI Figure2-109 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100BASE-T autosensing Ethernet port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Console port (CONSOLE) (6) System status LED (SYS) (7) SFP port (8) SFP port LED Figure2-110 Rear panel (1) Grounding screw (2) AC-input power receptacle...
Figure2-112 Rear panel (1) AC-input power receptacle (2) Grounding screw S3100V3-20TP-PWR-SI Figure2-113 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) SFP port LED (6) System status LED (SYS) (7) Mode LED (MODE) (8) Mode button...
S3100V3-28TP-PWR-SI Figure2-115 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) System status LED (SYS) (5) RPS status LED (RPS) (6) Mode LED (MODE) (7) SFP port LED (8) 10/100/1000BASE-T autosensing Ethernet port LED (9) Mode button (10) Console port (CONSOLE) (11) SFP port...
Page 120
DC: 180 VDC to 320 VDC • Max output power: 75 W • Rated input voltage range: –48 VDC to –60 VDC H3C PSR150-A & PSR150-D • Max input voltage range: –36 VDC to –72 VDC PSR150-D1 Series Power Supplies User •...
Ports and LEDs Ports Console port Table4-1 Console port specifications Item Serial console port Micro USB console port Connector type RJ-45 Micro USB Type B Compliant standard EIA/TIA-232 USB 2.0 Transmission baud rate 9600 bps (default) to 115200 bps • •...
USB port IMPORTANT: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices from all vendors on the S5560S-28DP-SI switch. If a USB device fails to operate on the switch, replace it with one from another vendor.
Item Specification • 1000 Mbps, full duplex Auto-MDI/MDI-X Supported Max transmission distance 100 m (328.08 ft) Transmission medium Category-5 (or above) twisted pair cable Compatible standards IEEE 802.3i, 802.3u, 802.3ab Switch models that provide a 10/100/1000BASE-T autosensing All switch models Ethernet port SFP port (S5008PV5-EI and S5008PV5-EI-HPWR switches) The SFP ports on the S5008PV5-EI and S5008PV5-EI-HPWR switches support GE SFP transceiver...
• As a best practice, use H3C transceiver modules and cables for the switch. • H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact your H3C sales representative or technical support engineer.
Page 125
Central Cable Max transmission FE SFP module Connector wavelength (nm) specifications distance SFP-FE-LH40-SM1 1310 9/125 µm, SMF 40 km (24.86 miles) SFP-FE-LH80-SM1 1550 9/125 µm, SMF 80 km (49.71 miles) TX: 1310 SFP-FE-LX-SM131 0-BIDI RX: 1550 9/125 µm, SMF 15 km (9.32 miles) TX: 1550 SFP-FE-LX-SM155 0-BIDI...
Page 126
GE SFP Central Modal transceiver Cable wavelength Connector bandwidth transmission module and specifications (nm) (MHz × km) distance cable 1310-D SFP-GE-LX-SM 1310 9/125 µm, SMF 10 km (6.21 miles) 1310-S SFP-GE-LH40- 40 km (24.86 1310 9/125 µm, SMF SM1310 miles) SFP-GE-LH40- 40 km (24.86 1310...
NOTE: • As a best practice, use only H3C SFP transceiver modules and cables for the SFP ports. • The H3C SFP transceiver modules and cables available for the SFP ports are subject to change over time. For the most recent list of SFP transceiver modules and cables available for the SFP port, contact your H3C Support or marketing staff.
Page 128
S5110V2-28P-SI switch, make sure the ambient temperature does not exceed 40°C (104°F). To use transceiver modules with All the SFP ports support GE SFP a maximum transmission transceiver modules and cables in distance greater than or equal to Table4-11. The SFP ports 1 to 26 80 km (49.71 miles) on the S5000V3-EI switch series on an S5024FV3-EI switch...
Page 129
GE SFP Central Modal Cable transceiver wavelength Connector bandwidth transmission specifications module/cable (nm) (MHz*km) distance 500 m (1640.42 275 m (902.23 62.5/125 µm, 220 m (721.78 550 m (1804.46 50/125 µm, 500 m (1640.42 SFP-GE-SX-MM850 275 m (902.23 62.5/125 µm, 220 m (721.78 10 km (6.21 9/125 µm, SMF...
Page 130
• As a best practice, use H3C transceiver modules and cables for the switch. • H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact your H3C sales representative or technical support engineer.
SFP+ port Table4-13 SFP+ port specifications Item Specifications Port type SFP+ port • GE SFP transceiver modules and cables in Table4-11 Supported transceiver modules and • cables 10-GE SFP+ transceiver modules and cables in Table4-14 • S5560S-28S-SI, S5560S-52S-SI, and S5560S-28F-SI switches Switch models that provide SFP+ ports •...
Page 132
2000 300 m (984.3 ft) 50/125 µm, 82 m (269.03 ft) SFP-XG-SX-M 66 m (216.54 ft) M850-S 33 m (108.27 ft) 62.5/125 µm, 26 m (85.30 ft) 2000 300 m (984.3 ft) 50/125 µm, 82 m (269.03 ft) SFP-XG-SX-M 66 m (216.54 ft) M850-E 33 m (108.27 ft) 62.5/125 µm,...
Page 133
50/125 µm, MMF 2000 300 m (984.25 ft) -MM-SR 10GBASE-LX-FD 10 km (6.21 1310 nm 9/125µm, SMF -SM-IR miles) H3C provides SFP+ cables of multiple lengths. For the available SFP+ cables, see Table4-14. Figure4-1 SFP+ cable (1) Connector (2) Pull latch 4-78...
• As a best practice, use H3C transceiver modules and cables for the switch. • H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact your H3C sales representative or technical support engineer.
Table4-18 Management Ethernet port LED description Management Ethernet port LED (ACT/LINK) status Description Steady green A link is present on the port. Flashing yellow The port is sending or receiving data. No link is present on the port. Power supply status LED Each removable power supply provides a status LED on the front panel to indicate its operating status.
LED mark Status Description the IRF member ID of the switch is 5. SFP port LED (S5500V3-36F-DP-SI switch) Table4-22 SFP port LED description Mode LED status SFP port LED status Description Steady green A link is present on the port. Steady green (Link/Active mode) Flashing green The port is sending or receiving data.
Page 137
Table4-24 10/100BASE-T autosensing Ethernet port LED and 10/100/1000BASE-T autosensing Ethernet port LED description 10/100BASE-T autosensing Ethernet port Mode LED status or 10/100/1000BASE-T Description autosensing Ethernet port LED status Steady green A link is present on the port. Steady green Flashing green The port is sending or receiving data.