Navair 17-20VQ-05 Technical Manual page 98

Digital voltmeters and digital multimeters
Table of Contents

Advertisement

NAVAIR 17–20VQ–05
CALIBRATION CHECKLIST
TEST INST (S)
Dana 4324 Multimeter (with or without Options)
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements
k Ranges:
4.3.2
1
"
10
"
100
M Ranges:
Affix a special calibration label stating:
1. The V ac frequency response has not been calibrated.
2. Only the 1 M range has been calibrated to the manufacturer tolerance;
all other resistance ranges have been calibrated to +0.2% of range.
114
MFG.
MODEL
MEASURED VALUES
NOMINAL
FIRST RUN
(3)
(4)
(k )
(k )
1.0000
10.000
100.00
(M )
(M
SER. NO.
OUT
SECOND RUN
CALIBRATION TOLERANCES
OF
TOL
(5)
(6)
0.9980 to
9.980
99.80
(7)
(k )
1.0020
to
10.020
to
100.20
(M
to
to
10.020
Page 2 of 2