CALIBRATION CHECKLIST
TEST INST (S)
Tektronix DM 501OPT01, or DM 501OPT02 Digital Multimeter
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements
TI
4.3.2
2 k
"
20 k
"
200 k
TI
4.3.2
2 M
"
10 M
Affix a special calibration label stating:
1. The DC and AC ammeter function have not been calibrated.
2. The TI temperature–measuring function has not been calibrated.
(Applicable only to DM501 & DM501–1)
66
MFG.
NOMINAL
(3)
Calibrator
(k )
k
1.0000
k
10.000
k
100.00
Calibrator
(M )
1 M
1.0000
10 M
10.000
MODEL
MEASURED VALUES
FIRST RUN
SECOND RUN
(4)
(5)
(k )
(M )
SER. NO.
OUT
CALIBRATION TOLERANCES
OF
TOL
(7)
(6)
(k )
0.9968
to
1.0032
9.968
to
10.032
99.68
to
100.32
(M )
0.9968
to
1.0032
9.948
to
10.052
Page 2 of 2