NAVAIR 17–20VQ–05
CALIBRATION CHECKLIST
TEST INST (S)
ME–229/ASM–35 or Electro Instruments, Inc. 851–8014A or 851–8014B Digital Multimeter
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements
TI & Calibrator
4.3.2
1 k
"
10 k
"
100 k
4.3.2
1 M
Affix a special calibration label stating:
"All resistance ranges have been calibrated to +0.2% of range."
52
MFG.
NOMINAL
(3)
(k )
range
1.0000
range
10.000
range
100.00
(M )
range
1.0000
MODEL
MEASURED VALUES
FIRST RUN
SECOND RUN
(4)
(5)
(k )
(M )
SER. NO.
OUT
CALIBRATION TOLERANCES
OF
TOL
(7)
(6)
(k )
0.9980
to 1.0020
9.980
to 10.020
99.80
to 100.20
(M )
0.9980
to 1.0020
Page 2 of 2