NAVAIR 17–20VQ–05
CALIBRATION CHECKLIST
TEST INST (S)
Dana 4300 Digital Multimeter
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements
k Ranges:
4.3.2
1
"
10
"
100
M Ranges:
"
1
"
10
Affix a special calibration label stating:
"The V ac frequency response has not been calibrated."
112
MFG.
MODEL
MEASURED VALUES
NOMINAL
FIRST RUN
(3)
(4)
(k )
(k )
1.0000
10.000
100.00
(M )
(M )
1.0000
10.000
SER. NO.
OUT
SECOND RUN
CALIBRATION TOLERANCES
OF
TOL
(5)
(6)
0.9968
9.968
99.68
0.9928
9.928
(7)
(k )
to
1.0032
to
10.032
to
100.32
(M )
to
1.0072
to
10.072
Page 2 of 2