NAVAIR 17–20VQ–05
CALIBRATION CHECKLIST
TEST INST (S)
Fluke 8500A/AEOPT1/2/5/8 as used with the TS 3846/ASM608 Inertial Measuring Unit Test Set
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements (5789)
TI Range
4.3.2
1 k
"
10 k
"
100 k
TI Range
"
1 M
"
10 M
"
100 M
*Affix a special calibration label to the TI stating:
"Calibration is performed in accordance with the usage requirement of the
TS3846/ASM608 Inertial Measuring Unit Test Set."
152
MFG.
NOMINAL
(3)
Calibrator
( )
k range
1000.0
k range
10000.0
k range
100000.
Calibrator
(M )
1 M
10 M
10 M
MODEL
MEASURED VALUES
OUT
FIRST RUN
SECOND RUN
TOL
(4)
(5)
(6)
( )
(M )
SER. NO.
CALIBRATION TOLERANCES
OF
(7)
( )
998.000 to
1002.00
9980.0
to
10020.0
99980.0 to
100020
(M )
to
to
to