Navair 17-20VQ-05 Technical Manual page 97

Digital voltmeters and digital multimeters
Table of Contents

Advertisement

CALIBRATION CHECKLIST
TEST INST (S)
Dana 4324 Multimeter (with or without Options)
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.1
Direct–Voltage Measurements
TI Range
4.1.3
+10 V
"
+10 V
"
+10 V
"
+10 V
"
+10 V
"
+10 V
"
+10 V
"
+10 V
"
+10 V
"
+10 V
"
10 V
4.1.6
–10 V
TI Range
4.1.9
0.1 V
"
1 V
"
100 V
"
1000 V
TI 0.1 V Range
4.1.13
10 V LSD
4.1.14
10 V LSD
4.2
Alternating–Voltage Measurements
Range
4.2.2
1 V
"
10 V
"
10 V
"
100 V
"
100 V
"
1000 V
MFG.
NOMINAL
(3)
Calibrator
(V)
10 V x 0
0.000
10 V x .1
1.000
10 V x .2
2.000
10 V x .3
3.000
10 V x .4
4.000
10 V x .5
5.000
10 V x .6
6.000
10 V x .7
7.000
10 V x .8
8.000
10 V x .9
9.000
10 V x 1
10.000
10 V x 1
10.000
Calibrator
(V)
1 V x .1
0.10000
1 V x 1
1.0000
100 V
100.00
100 V
100.0
V)
520
480
Calibrator
(V)
400 Hz–1 V
1.0000
400 Hz–10 V
10.000
4 kHz–10 V
10.000
4 kHz–10 V
10.00
400 Hz–100 V
100.00
400 Hz–100 V
100.0
MODEL
MEASURED VALUES
FIRST RUN
SECOND RUN
(4)
(5)
(V)
(V)
( V)
(V)
NAVAIR 17–20VQ–05
SER. NO.
OUT
CALIBRATION TOLERANCES
OF
TOL
(7)
(6)
(V)
–0.002 to
0.002
0.998
to
1.002
1.998
to
2.002
2.998
to
3.002
3.998
to
4.002
4.997
to
5.003
5.997
to
6.003
6.997
to
7.003
7.997
to
8.003
8.997
to
9.003
9.997
to
10.003
9.997
to
10.003
(V)
0.09993 to
0.10007
0.9997 to
1.0003
99.97
to
100.03
99.8
to
100.2
( V)
510
to
530
470
to
490
(V)
0.9972 to
1.0028
9.972
to
10.028
9.972
to
10.028
9.90
to
10.10
99.72
to
100.28
99
to
101
Page 1 of 2
113

Advertisement

Table of Contents
loading

Related Products for Navair 17-20VQ-05

Table of Contents