Navair 17-20VQ-05 Technical Manual page 48

Digital voltmeters and digital multimeters
Table of Contents

Advertisement

NAVAIR 17–20VQ–05
CALIBRATION CHECKLIST
TEST INST (S)
Systron Donner 9310, 9320, 9330, 9340, or 9340–5B Digital Multimeter
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements
TI & Calibrator
4.3.2
1000
"
Range & Calibrator
4.3.2
10 k
"
100 k
"
1000 k
4.3.2
10 M
Affix a special calibration label stating: "The 100 mV V dc range has not been calibrated,
and all resistance ranges have been calibrated to +0.2% of range."
NOTE: If the TI is a Systron Donner 9320, 9340, or 9340–5B, subjoin another statement to the
special calibration label stating: "The V ac function has been calibrated up to 50 kHz only."
56
MFG.
MODEL
MEASURED VALUES
NOMINAL
FIRST RUN
(3)
(4)
( )
( )
1000.0
(k )
(k )
10.000
100.00
1000.0
(M )
(M )
10.000
SER. NO.
OUT
SECOND RUN
CALIBRATION TOLERANCES
OF
TOL
(5)
(6)
Assigned: +0.2%
998.0
9.980
99.80
998.0
9.980
Page 2 of 2
(7)
( )
to
1002.0
(k )
to
10.020
to
100.20
to
1002.0
(M )
to
10.020

Advertisement

Table of Contents
loading