NAVAIR 17–20VQ–05
CALIBRATION CHECKLIST
TEST INST (S)
AN/USM–216, ME–310, McDonnell 53E04005, or Cubic 93–1015–1 SECTION D
Digital Multimeter
NA 17–20VQ–05
PROC. NO.
PROCEDURE
FUNCTION TESTED
STEP
NO.
(2)
(1)
4.3
Resistance Measurements
TI & Calibrator
4.3.2
1 k
"
10 k
"
100 k
"
1000 k
"
10000 k
Affix a special calibration label stating:
"The ratio measurement function and the freq. response of the V ac
function have not been calibrated.
All resistance ranges have been calibrated to +0.2% of range."
48
MFG.
MODEL
MEASURED VALUES
NOMINAL
FIRST RUN
(3)
(4)
(k )
(k )
1.00000
10.0000
100.000
1000.00
10000.0
SER. NO.
OUT
SECOND RUN
CALIBRATION TOLERANCES
OF
TOL
(5)
(6)
0.99800
9.9800
99.800
998.00
9980.0
Page 2 of 2
(7)
(k )
to 1.00200
to 10.0200
to 100.200
to 1002.00
to 10020.0