IDEC WindO/I-NV4 User Manual page 83

Automation organizer
Table of Contents

Advertisement

Monitors
Command
Start/Stop Monitor
Go Offline/Online
Screens
Object List
Custom
Batch
External Devices
Open Current Screens
Back
Forward
First Screen
Previous Screen
Go to
Screen Number
Screen
Next Screen
Last Screen
Simulator
Command
Load Value of Device Address
(External Device, LK, LKR)
Simulator
and Run
Clear Value of Device Address
(External Device, LK, LKR)
and Run
Communication
Command
Setup
Starts or stops monitoring the MICRO/I with WindO/I-NV4. An external device
is required when configuring it.
Switch the MICRO/I to Offline Mode or Online Mode. Under Offline Mode, you
can change values of device addresses with WindO/I-NV4 and check the
operation of project data on the MICRO/I.
Shows or hides the Screen Monitor window.
Displays a value of device address in a popup and emphasizes the object that
is satisfying the trigger condition in the object list or script editor.
Shows or hides the Custom Monitor window.
Shows or hides the Batch Monitor window.
Shows or hides the External Device Monitor window during 1:N
communication.
Opens a monitored screen in the editing window.
Returns to the Base Screen that was displayed immediately before the screen
was changed.
Advances to the Base Screen that was displayed immediately before the
screen was changed with the Back command.
Switches to the Base Screen with the smallest screen number in the project data.
Switches to the Base Screen with a screen number one smaller than the Base
Screen currently displayed. If the screen numbers are not consecutive
numbers, this command switches to the closest number.
Switches to the Base Screen with a specified number.
Switches to the Base Screen with a screen number one larger than the Base
Screen currently displayed. If the screen numbers are not consecutive
numbers, this command switches to the closest number.
Switches to the Base Screen with the largest screen number in the project
data.
Launch Simulator.
Load the project data, and the values of device addresses on the external
devices, HMI Keep Relays (LK), and HMI Keep Registers (LKR), and then
launch Simulator.
Clear Value of Device Address (External Device, LK, LKR) and Run
Configures the communication target and communication conditions between
the target and the MICRO/I or between the computer and the MICRO/I.
WindO/I-NV4 User's Manual
3 Configuration & Functions
Description
Description
Description
2
2-51

Advertisement

Table of Contents
loading