Line Spacing
Selects the specification method for line spacing in the list and configures the line spacing.
Set with Number of Lines:
Specifies the number of lines for the message to display for one alarm line.
Enter the number of lines. The range that can be specified varies based on the vertical size of the
base screen and the character height. When you enter the number of lines, the line spacing is
automatically calculated according to the display area.
Number of lines X Character height = Line spacing (dots)
The character height setting varies based on the model.
HG2J-7U:
Size is 16.
Number of Lines Character height
1
Number of Lines Character height
2
Number of Lines Character height
3
HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G/1P:
Number of Lines Magnification H
1
Number of Lines Magnification H
2
Number of Lines Magnification H
3
Since the alarm line spacing is adjusted with the number of lines for the message fixed, this option is
convenient to use when displaying multi-line messages.
*3 Advanced mode only
Calculation formula
Size
Line Spacing
×
24
=
24 dots
Current fault
Pump fault
Line Spacing
Current fault
×
24
=
48 dots
has occurred
Pump fault
has occurred
Line Spacing
Current fault
×
24
=
72 dots
has occurred
Pump fault
has occurred
Line Spacing
×
1
× 16 = 16 dots
Current fault
Pump fault
Line Spacing
Current fault
×
1
× 16 =
32 dots
has occurred
Pump fault
has occurred
Line Spacing
Current fault
×
1
× 16 =
48 dots
has occurred
Pump fault
has occurred
WindO/I-NV4 User's Manual
Line Spacing
When the message is 2 lines,
2nd line is not shown.
Magnification H x 16
When the message is 2 lines,
2nd line is not shown.
Number of Lines Magnification H
3
×
2
× 16 =
8 Alarm Log Display
Current fault
Line Spacing
96 dots
has occurred
Pump fault
has occurred
10-163