IDEC WindO/I-NV4 User Manual page 862

Automation organizer
Table of Contents

Advertisement

1 Bar Chart
Trigger Condition Tab
The Trigger Condition tab is displayed in Advanced mode.
The bar chart is enabled while the condition is satisfied, and it is disabled while the condition is not satisfied. Select
the operation when the condition is not satisfied as Not display Chart data or Not update Chart data under
While not satisfying the condition.
Example: When Trigger Type is While ON, Device Address is LM0, and While not satisfying the condition is Not
display Chart data
While LM0 is 0, the condition is not satisfied and the bar chart is not displayed.
While LM0 is 1, the condition is satisfied and the bar chart is displayed.
Data over does not operate for hidden bar charts. Data over is reported if the minimum or maximum is
exceeded when the bar chart changes from hidden to displayed.
Trigger Type
Selects the condition to enable the bar chart from the following.
Always visible:
11-14
Condi on
Not
sa sfied
Condi on
Sa sfied
The bar chart is always enabled.
Ch1 data
50
Ch2 data
10
Display
0
50
100
Update
WindO/I-NV4 User's Manual