Abbreviations, Generic Terms, and Terminology Used in this Manual
Item
HG2J-7U
HG5G-V
HG4G-V
HG4G
HG3G-V
HG3G
HG2G-V
HG2G-5F
HG2G-5T
HG1G
HG1P
HG5G/4G/3G/2G-V
HG5G/4G/3G-V
HG4G/3G
HG2G-5F/-5T
HG1G/1P
MICRO/I
External Device
Device Address
System Area
Device Link Communication
DM Link Communication
User Communication
External Device Communication
Sub Host Communication
BACnet Communication
O/I Link
O/I Link Master
O/I Link Slave
WindO/I-NV4
Operating System
System Software
Project
Manager
Setup
Abbreviations, Generic Terms, and Terminology Used in this Manual
The name is short for MICRO/I HG2J-7UT22TF-B.
The name is short for MICRO/I HG5G-VFXT22MF-B.
The name is short for MICRO/I HG4G-VCXT22MF-B.
The name is short for MICRO/I HG4G-CJT22*F-B.
The name is short for MICRO/I HG3G-V*XT22MF-*.
The name is short for MICRO/I HG3G-*JT22*F-*.
The name is short for MICRO/I HG2G-V5FT22TF-*.
The name is short for MICRO/I HG2G-5FT22TF-*.
The name is short for MICRO/I HG2G-5T*22TF-*.
The name is short for MICRO/I HG1G-4VT22TF-*.
The name is short for MICRO/I HG1P-ST32*.
The format used to refer to HG5G-V, HG4G-V, HG3G-V and HG2G-V.
The format used to refer to HG5G-V, HG4G-V and HG3G-V.
The format used to refer to HG4G and HG3G. HG4G-V and HG3G-V is not included.
The format used to refer to HG2G-5F and HG2G-5T.
The format used to refer to HG1G and HG1P.
Generic term used to refer to the HG2J-7U, HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T,
HG1G/1P.
Generic term used to refer to a PLC or micro computer that is connected to and
communicates with the MICRO/I.
Memory that is capable of storing values in unit of bits or words loaded on the MICRO/I
and external device.
Device address area that is pre-allocated for exchanging screen management, error
information, and clock data between the MICRO/I and an external device.
A communication method that performs communication with the external device
according to the setting of the screen and without a program.
A communication method that reads to or writes value to external devices using the
MICRO/I's dedicated DM Link memory.
A communication method which performs communication with external devices such as
barcode readers and inverters.
Generic term used to refer to Device Link Communication and DM Link Communication.
A communication method that performs communication with external device according
to the set device address list and without a program.
A communication method for building management systems such as air conditioning,
lighting and crime prevention.
A connection format that enables connections of up to 16 units of MICRO/I with high-
speed communication of 115,200bps.
The MICRO/I unit that is directly connected to external device on the O/I Link network.
The MICRO/I units that are not directly connected to external device on the O/I Link
network.
Integrated configuration software application for creating projects of the MICRO/I.
Software used to manage and control system software. Only HG2J-7U supports the update.
Software required for operating MICRO/I.
Data including image data required for operating the MICRO/I, which is created with
WindO/I-NV4.
WindO/I-NV4 provides tools to manage pictures, text and script etc. With the Managers,
you can create and manage them in your project.
Generic term used to refer to the common settings in the project.
WindO/I-NV4 User's Manual