IDEC WindO/I-NV4 User Manual page 689

Automation organizer
Table of Contents

Advertisement

Value:
Switches the picture to display according to the value of the device address.
Example: When Value is selected and the trigger device addresses D0 are allocated to the
following pictures.
Switches the picture to display according to the value of the device address.
Trigger device address
Trigger Device Address: Specifies the word device to use as the condition for switching pictures.
When the size of pictures to switch differs and the Dynamic Size check box is cleared, all the pictures are
displayed with the same size as Pic0.
Fixed Period:
Switches the pictures to display at a regular interval in picture number order on the picture list.
Example: When Fixed Period is selected and the following pictures are allocated to the picture list.
Switches the pictures to display at a regular interval in picture number order on the
picture list.
Interval:
Repeat:
When Fixed Period is selected, the picture may not be displayed when the interval is shorter than the scan
time for the screen on the MICRO/I. The maximum value for the MICRO/I scan time can be checked by the
value of HMI Special Data Register LSD4. Refer to Chapter 33 "HMI Special Data Register (LSD)" on page
33-8.
Trigger device address D0 value
Picture
Pic0
0
D0 value
Picture to display
Pic 0
Action
Display picture for 0
Click
to display the Tag Editor. For the device address configuration
procedure, refer to Chapter 2 "5.1 Device Address Settings" on page 2-70.
This option can only be configured when Bit Number or Value is
selected.
Picture
Picture list number
Pic0
Pic1
Regular interval
Regular interval
Interval
5 x 100 ms
5 x 100 ms
Picture to display
Pic 0
Action
Display picture
Display picture
for bit 0
Specifies the interval to switch pictures as 2 to 600 (100 ms units).
This option can only be configured when Fixed Period is selected.
Select this check box to repeat displaying pictures from the start of the picture
list when the picture at the end of the list is displayed.
This option can only be configured when Fixed Period is selected.
WindO/I-NV4 User's Manual
0
1
2
Pic1
Pic2
1
2
Pic 1
Pic 2
No picture
Display picture for 1
Display picture for 2
Pic2
Regular interval
5 x 100 ms
Pic 1
Pic 2
If the Repeat check box is cleared,
Display picture
stop switching the picture list.
for bit 1
for bit 2
3 Picture Display
3
If the value of device
address has no picture
associated with it, display
nothing.
10-61
10

Advertisement

Table of Contents
loading

Table of Contents