1 Pilot Lamp
While OFF: Turns on the Pilot Lamp when the value of device address is 0.
While satisfying the condition:
Data Type:
Selects the type of data handled by the conditional expression for the ON condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 "1.1 Available Data" on page 2-1.
Device Address: Specifies the bit device or the bit number of the word device to serve as the ON condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.
Click
"5.1 Device Address Settings" on page 2-70.
Condition:
Specifies the conditional expression for the ON condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type.
Click
configuration procedure, refer to Chapter 2 "5.2 Setting Conditional Expressions" on page 2-73.
Comment:
Used for entering a comment for the ON condition. The maximum number is 80 characters.
Visible Condition
The Pilot Lamp is displayed while the condition is satisfied. The Pilot Lamp is hidden while the condition is not
satisfied.
Example: When Trigger Type is While ON and Device Address is LM0
While LM0 is 0, the condition is not satisfied and the Pilot Lamp is hidden.
While LM0 is 1, the condition is satisfied and the Pilot Lamp is displayed.
9-10
1
Value of
device address
0
Pilot Lamp status
On
Turns on the Pilot Lamp when the condition is satisfied.
Satisfied
Condition
Not satisfied
Pilot Lamp status
Off
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2
to display the Trigger Condition Settings dialog box. For the conditional expression
LM0 :
0
Condition
Not
satisfied
LM0 : 1
Condition
Satisfied
WindO/I-NV4 User's Manual
Off
On
Off
On
Off
On
MICRO/I
Hide
Show
Off
On
On
Off