IDEC WindO/I-NV4 User Manual page 881

Automation organizer
Table of Contents

Advertisement

Specifying Date and Time with Values of device addresses
Using this option requires the sequential address number of 6 words starting from the specified device address. The
data is handled as BCD4(B) values in the order of year, month, day, hour, minute, and second.
Example: Top Device Address is LDR100, and the date and time is October 1 2018 12:01:30.
(the address number of Top Device Address)
Scale
Show Ticks:
Select this check box to display a scale on a X-axis.
Major Divisions:
Minor Divisions:
Color:
If the area for displaying the scale is small, the scale will not be displayed properly.
Read source
Date and time data
LDR 100
2018
+1
LDR 101
+2
LDR 102
+3
LDR 103
+4
LDR 104
+5
LDR 105
Enter the number of major scale divisions (1 to 20).
Enter the number of minor scale divisions (1 to 20).
Selects the color of scales (color: 256 colors, monochrome: 16 shades).
Click Color to display the Color Palette. Select a color from the Color
Palette.
WindO/I-NV4 User's Manual
(Year)
10
(Month)
1
(Day)
12
(Hour)
1
(Minute)
30
(Second)