Advertisement

Action Mode
Select the behavior of the button from the following. This option is displayed only when Printer is selected in Output to.
Print Screen:
Outputs a screenshot of the current screen to the printer or the external memory device
*1
Cancel Printing
: Cancels printout to the printer.
View Switching Method
Select how to display the ON/OFF status of the button.
Button:
Pressing the button changes the drawing object displayed.
Device Address: The drawing objects assigned to the OFF and ON states are displayed when the value of the device
address is 0 and 1, respectively. Specifies the device address used to switch the drawing object
display.
Click
"5.1 Device Address Settings" on page 2-70.
No Image:
The button is not displayed on the screen. The button appears as a dashed line frame on the edit
screen. Pressing the corresponding area on the MICRO/I activates the assigned function. If No
Image is selected, the settings for View and Registration Text are disabled.
Selecting Device Address in View Switching Method allows you to create an illuminated pushbutton.
The illuminated pushbutton switches state (or image) according to ON or OFF state of the device address,
allowing you to display the state of a device that is being operated.
Example: When you set an external device address 'M0' as Device Address in View Switching Method,
if the value of M0 changes, the display image will switched according to the value of M0 even if
the button is not pressed.
OFF image:
ON image:
View Switching Method (Device Address): M0
• These operations cannot be performed simultaneously.
- Outputting to the external memory device by pressing the Print Button.
- Outputting to the printer by pressing the Print Button
- Printing alarm logs
• While the screenshot is being output to the external memory device, the Print Button or Print Command
cannot output to one. Also, during these situations, the value of HMI Special Relay LSM24 or LSM25
changes to 1. For details, refer to Chapter 33 "HMI Special Relay (LSM)" on page 33-2.
• It may take some time to output screenshots when copying files using the USB Autorun function or a Key
Button.
• MICRO/I cannot stop printing in the middle of a page, even when the print job is canceled. Print jobs
after the current print job are canceled after the current page finishes printing.
The maximum number of screenshots that can be captured (1 to 999) can be set in HMI Special Data
Registers LSD65. (Default: 99)
*1 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F only
*3 Advanced mode only
*3
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2