IDEC WindO/I-NV4 User Manual page 843

Automation organizer
Table of Contents

Advertisement

Trigger Condition Tab
The Trigger Condition tab is displayed in Advanced mode.
The Calendar is enabled while the condition is satisfied, and it is disabled while the condition is not satisfied. When
disabled, the plate and flange are displayed, but the time is not displayed. However, if the Not show Calendar check
box under While not satisfying the condition is selected, the plate and flange are also hidden and the part image
is not displayed.
Example: When Trigger Type is While ON, Device Address is LM0, and the Not show Calendar check box
under While not satisfying the condition is cleared
While LM0 is 0, the condition is not satisfied and the Calendar does not display the time.
While LM0 is 1, the condition is satisfied and the Calendar displays the time.
Trigger Type
Selects the condition to enable the Calendar from the following.
Always visible: The Calendar is always enabled.
Calendar state
LM0 :
0
Condition
Not
satisfied
LM0 : 1
Condition
Satisfied
Always show time
WindO/I-NV4 User's Manual
MICRO/I
Hide
time
Show
time
12/07 13:45
12/07 13:45
11 Calendar
10
10-215

Advertisement

Table of Contents
loading

Table of Contents