IDEC WindO/I-NV4 User Manual page 826

Automation organizer
Table of Contents

Advertisement

10 Numerical Display
Trigger Condition Tab
The Trigger Condition tab is displayed in Advanced mode.
The Numerical Display is enabled while the condition is satisfied, and it is disabled while the condition is not satisfied.
Select the operation when the condition is not satisfied as Not display Numerical data, Not update Numerical
data, or Not show Numerical Display under While not satisfying the condition.
Example: When Trigger Type is While ON, Device Address is LM0, and While not satisfying the condition is
Not display Numerical data
While LM0 is 0, the condition is not satisfied and the Numerical Display does not display the number.
While LM0 is 1, the condition is satisfied and the Numerical Display displays the number.
Data over does not operate for hidden Numerical Displays. Data over is reported if the minimum or
maximum is exceeded when the Numerical Display changes from hidden to displayed.
Trigger Type
Selects the condition to enable the Numerical Display from the following.
Always visible: The Numerical Display is always enabled.
Display
10-198
LM0 :
Condition
Not
satisfied
LM0 : 1
Condition
Satisfied
Data
99
100
99
100
Update
Update
WindO/I-NV4 User's Manual
MICRO/I
0
1234
101
102
101
102
Update
Update
Update
Hide
number
Show
number
103
104
105
103
104
105
Update
Update

Advertisement