Memory Channel Selections (Memory Ch); Travel Speed Selections ( ); 3.3.4 Wire Feed Speed Selections; Welding Current Selections (Current) - Kemppi MagTrac F 61 Manual

Hide thumbs Also See for MagTrac F 61:
Table of Contents

Advertisement

3.3.2 Memory channel selections (MEMORY CH)

Menu item
CH MODE *
LOAD CH
SAVE CH *
*) These menu items are not available with FastMig Pulse. CH MODE setting is always ON, and
the channel parameter values are saved automatically.
To change the memory channel in use, do the following
1.
In MEMORY CH menu, select CH MODE: ON.
2.
In MEMORY CH menu, select LOAD CH and press the multi-function knob.
3.
Turn the multi-function knob to select the memory channel number you want to use.
(You can scroll numbers also with the lower soft key 'CH' . )
4.
When the desired channel number is displayed, press the upper soft key 'BACK' .
If the welding parameter values come from a memory channel, you cannot change any of
NOTE!
the values at the MagTrac menu while operating the carriage.
3.3.3 Travel speed selections (
Select this menu item to change the carriage travel speed in the range of 150 - 1500 mm/min.
In cycle welding, the carriage travels non-welded sections at the maximum speed of 1800
mm/min.
When the speed reaches 1000 mm/min, the unit of measure changes automatically to
NOTE!
m/min.
To change carriage travel speed, do the following
1.
Press the multi-function knob on the travel speed menu item.
2.
Turn the multi-function knob to change the speed.
3.
Press the multi-function knob to accept the new speed.

3.3.4 Wire feed speed selections (

Select this menu item to change the wire feed speed. Note that the welding current value
changes automatically to reflect the new wire feed speed.
To change wire feed speed, do the following
1.
Press the multi-function knob on the wire feed speed menu item.
2.
Turn the multi-function knob to change the speed.
3.
Press the multi-function knob to accept the new speed.

3.3.5 Welding current selections (CURRENT)

Select this menu item to change the welding current. Note that the wire feed speed value
changes automatically to reflect the new welding current.
To change welding current, do the following
1.
Press the multi-function knob on the CURRENT menu item.
2.
Turn the multi-function knob to change the current value.
3.
Press the multi-function knob to accept the new current.
© Kemppi Oy / R01
Values
Description
ON, OFF, SET
Select the memory channel usage mode.
ON = Memory channels are enabled, and you can select the
channel to be used. Parameters can be edited on the carriage
panel
OFF = Memory channels are disabled. You can set the welding
parameters on the carriage panel, but they are not stored in the
memory.
SET = Memory channel contents can be edited and saved. You
can change the welding parameters and save your changes into
the active memory channel.
0...9
Select memory channel to load. Enabled only when CH MODE
selection is ON.
0...9
Select memory channel to save. Enabled only when CH MODE
selection is SET.
)
)
EN
11

Advertisement

Table of Contents
loading

Table of Contents