Section 2 Specifications

2-3-3 Analog input/output unit (Type: NA0AW06-MR)

(1) Names
The jumper pins in the analog input/output unit are used to change the analog signal range and digital value range. Therefore,
remove the upper cover and control board when setting the jumper pin.
2) Terminal block
Expansion connector (IN)
1) Status indication LED
2) Terminal block
3) JP1
Pin layout of control board
(When the upper cover is removed)
<Notes on mounting/removing the upper cover and control board>
• When handling the analog unit, remove it from the control panel, turn off the power, and disconnect other units.
• The procedure for handling the upper cover and printed circuit board, see "Appendix 1 Unit Handling Procedure."
• Before mounting/removing the upper cover or handling the printed circuit board, be sure to eliminate static electricity.
NA0AW06-MR
CH0
CH1
4) JPA
U
B
6) JP3
5V
D/A
6) JP4
10V
JP1
A/D
Pin layout of I/O board
(When the control board is removed)
Expansion connector (OUT)
Nameplate
CH0
CH1
5) JPB
7) JP5 (CH0) to JP8 (CH3)
2-19