Sequence Mode - Fuji Electric Faldic-a RYS-R Series User Manual

Ac servo system
Table of Contents

Advertisement

7.3 Sequence mode

In the sequence mode, the amplifier current status and the alarm detection history can be displayed.
Press the MODE key to display [
: Sequence
: Sub-mode
: Alarm detection
: Alarm history
: Amplifier setting
: Motor setting
: Station No. indication
(1) Sequence
Indicates the amplifier output signal status and operation status.
 Speed zero
 Speed arrival
 Ready
Indexing end
Deviation zero
Forced stop detection
* The corresponding LED goes on when the above
each output signal is on.
Remark : When power is applied to the amplifier, the sequence of the sequence mode is displayed. The type of indication at power on can
be changed by system para. 89 setting.
] and then press the ENT key for more than 1 [s].
ENT (1 [s] or more)
            
ESC
Indication
Description
In base-off condition, the motor has no driving force and in
free-run status. (Figure above)
The motor can rotate.
The amplifier has received a forced stop signal and stops with
the speed zero signal.
7-5
MHT260a (Engl.)