Developer Recirculation System

Removing the Recirculation Pump B5

[1]
Deenergize the PROCESSOR. See page 1-5.
[2]
Lift the TOP COVER.
[3]
Remove the DRIVE SIDE PANEL.
[4]
Remove the SPLASH COVER.
[5]
Remove the 2 SCREWS, the 2 LOCK
WASHERS, and the 2 WASHERS that hold
the RECIRCULATION PUMP to the PUMP
BASE PLATE.
[6]
Move the RECIRCULATION PUMP for better
access to the HOSES.
[7]
Use 4 CLAMPS TL-2170 on the 2 developer
HOSES and on the 2 fixer HOSES to the
RECIRCULATION PUMP.
[8]
Loosen the 4 HOSE CLAMPS and remove the
2 developer HOSES and the 2 fixer HOSES
from the RECIRCULATION PUMP.
[9]
Disconnect the CONNECTOR P/J 12.
[10]
Remove the RECIRCULATION PUMP.
[11]
Reverse the above procedure to install a new
RECIRCULATION PUMP.