• Use SEALANT TL-3230 on the threads of the FIXER HEATER when installing the FIXER
HEATER in the FIXER THERMOWELL. Use only TL-3230. Any other SEALANT will corrode
the plastic in the THERMOWELL. See the instructions packed with the SEALANT.
• The HEATER LOCATOR must be in the correct position.
• Do not overtighten the parts when you install the FIXER HEATER.
[11]
Check that the internal HEATER LOCATOR is in the correct position inside the FIXER THERMOWELL.
See the figure below.
[12]
Reverse the above procedure to install a new FIXER HEATER and to assemble the PROCESSOR.
[13]
Check for leakage at the FIXER THERMOWELL.
Checking the Position of the Heater Locator inside the Thermowell
5-10
HEATER
8.38 0.25 cm
LOCATOR
+
-
+
(3.3 0.1 in)
-
HEATER
LOCATOR
+
13.9 0.25 cm
-
+
(5.5 0.1 in)
-
H104_0444BCA
H104_0444BA