Filling The Developer Tank - Kodak Prostar Operator's Manual

Archive processor 220-240 v
Table of Contents

Advertisement

Filling the developer tank

8
If the Archive Processor is powered up, shut it off before you remove
the developer tank or turn off the water. This prevents water from
overflowing the water jacket later when you reinsert the tank.
NOTE: Use proper precautions when using developer. Review the
MSDS for the developer.
1. Pull the gear cover back and lift the developer tank out of the
Archive Processor. The developer tank is labeled with a D.
2. Fill the developer tank with Kodak Prostar Plus Developer, or
equivalent, until the level reaches the fill line (approximately
½ gallon or 1.3 liters).
3. Wrap the overflow tubing closely around the right side of the
developer tank.
4. Hold the gear cover back and slowly and carefully lower the
developer tank into the first position in the Archive Processor.
NOTE: Make sure the tank is fully seated and level with the fill line
toward the rear of the Archive Processor.
5. Fill the squeeze bottle with developer.
The squeeze bottle will be needed later to top off the developer tank
between processing rolls of film.
A-62051 May 2008