Section 3: Replenishment Solutions
Mixing the Developer and Fixer Replenishers
Use KODAK RP X-OMAT Developer Replenisher and KODAK RP X-OMAT LO Fixer and Replenisher. Avoid
contaminating the chemical solutions by intermixing them. Clean the Pitcher ( 43 ) after each use. Carefully follow
the mixing directions packed with the Replenishers. The 1000 Processors are set before shipment to be used in the
Flooded Mode. Unless the mode of your Processor has been changed, you must add KODAK RP X-OMAT
Developer Starter to the Developer Replenishment Container ( 35 ) at the rate of 3 fl oz/gallon or 90 mL/3.8 L. If you
are not sure whether the Processor is set to Flooded or Regular Mode, ask your service provider.
Filling the Tanks in the Processor
Filling the Tanks
Figure 7
H164_0024ACA
39
H164_0024AC
Important
Avoid contamination of the developer by removing any splashes of fixer from the empty Developer Tank. Clean the
Pitcher after each use.
[8] Clean the Pitcher ( 43 ) under running water.
[9] Wipe the Developer Tank ( 39 ) with a damp towel.
[10] Install the Developer Rack ( 12 ) .
[11] Pour 3.8 litres of the developer solution mixed on Page
added to the Developer Replenishment Container, add 3 fl oz (90 mL) of Starter to the Pitcher.
[12] Carefully pour the developer solution into the Developer Tank ( 39 ) .
[13] Install the:
• Evaporation Cover
• Crossover
• Top Cover on the Processor
[14] Insert the Drain Hoses ( 24, 25, 28 ) into the correct Drain Containers ( 38, 37, 36 ) .
• Do not insert the Hoses too far into the Containers.
• Do not bend the Hoses.
[15] Turn on the power main circuit breaker at the wall or plug in the Processor.
[16] Press the " | " on the "Power" Switch ( 20 ) to turn the Processor on.
9B8942 – November 1997
43
40
[1] Press the " O " on the "Power" Switch ( 20 ) to turn
the Processor off.
[2] Turn off the main power circuit breaker at the wall
of the darkroom or unplug the Processor.
[3] Turn off the water to the Processor.
[4] Check that the Developer and Fixer Drain Valves (
22, 23 ) are closed.
[5] Remove the Evaporation Cover ( 11 ) , the
Crossover ( 14 ) that has the "D" and "F" on it, and
the Developer Rack ( 12 ) .
[6] Rinse the Pitcher ( 43 ) .
[7] Pour 3.8 litres of the fixer solution mixed on Page
11
into the Pitcher ( 43 ) . Then, with the Fixer
Rack ( 15 ) in place, carefully pour the solution into
the Fixer Tank ( 40 ) .
11
into the Pitcher. If Developer Starter has not been
Replenishment Solutions
11